Home>PLC>Siemens 6SN1145-1BA02-0CA2 SIMODRIVE 611 36/47 kW Infeed/regenerative feedback module

Hot Categories

Siemens 6SN1145-1BA02-0CA2 SIMODRIVE 611 36/47 kW Infeed/regenerative feedback module

Siemens 6SN1145-1BA02-0CA2 SIMODRIVE 611 36/47 kW Infeed/regenerative feedback module

Item NO.: 3769704

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6SN1145-1BA02-0CA2 SIMODRIVE 611 36/47 kW Infeed/regenerative feedback module
  • Item NO.3769704
  • Weight14.0000 kg = 30.8647 lb = 493.8355 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-09-15
SIMODRIVE 611 | 36/47 kW | REGENERATIVE LINE MODULE

Siemens 6SN1145-1BA02-0CA2 SIMODRIVE 611 36/47 kW Infeed/regenerative feedback module

A 36/47 kW infeed/regenerative feedback module with internal cooling for a compatible modular drive group.

BrandSiemens
Model6SN1145-1BA02-0CA2
Product TypeSIMODRIVE 611 Infeed/regenerative feedback module
01

Key Information

6SN1145-1BA02-0CA2 is a Siemens SIMODRIVE 611 infeed/regenerative feedback module rated at 36/47 kW. The unit combines closed-loop regulated operation with internal cooling.

This article forms the mains-side energy interface for a compatible 611 drive group. Its exact suffix keeps the power class, contact arrangement and hardware revision distinct from visually similar line modules.

02

Functions

  • Feeds the SIMODRIVE 611 DC link from the plant mains supply.
  • Returns regenerative motor energy to the mains within the documented system configuration.
  • Provides the 36/47 kW module class with closed-loop regulated behavior.
  • Uses internal cooling and the specified mains-contact interface.
  • Supports coordinated operation with compatible 611 power modules and controls.
03

Specifications

Manufacturer Siemens
Article Number 6SN1145-1BA02-0CA2
Product Family SIMODRIVE 611
Module Type Infeed/regenerative feedback module
Rated Capacity 36/47 kW
Regulation Closed-loop regulated
Cooling Internal cooling
Mains Interface Mains contactor with break contact
Lifecycle Cancelled product; supplied through spare-parts channels
Lifecycle Date 1 April 2015
Earlier Article 6SN1145-1BA02-0CA1
04

Installation

  • Isolate the mains and confirm complete DC-link discharge before handling 6SN1145-1BA02-0CA2.
  • Compare the 36/47 kW rating, contact arrangement and cooling path with the removed article.
  • Label mains, DC-link, control and protective wiring before disconnection.
  • Inspect busbars, precharge hardware, fuses, contactor circuits and fan path.
  • Commission 6SN1145-1BA02-0CA2 only after verifying system protection and regenerative operation.
05

Lifecycle

  • 6SN1145-1BA02-0CA2 is managed as cancelled product; supplied through spare-parts channels.
  • 6SN1145-1BA02-0CA1 is an earlier related article; preserve revision-specific compatibility.
  • Retain cabinet drawings, connected-axis inventory and failure history with the spare record.
  • Plan repair or migration before the installed legacy stock becomes a production constraint.
07

FAQ

What rated capacity identifies 6SN1145-1BA02-0CA2?

6SN1145-1BA02-0CA2 is identified by a 36/47 kW rating in the SIMODRIVE 611 line-module family.

What cooling arrangement belongs to 6SN1145-1BA02-0CA2?

6SN1145-1BA02-0CA2 uses internal cooling; the cabinet airflow and heat-removal path must remain suitable.

Which mains interface must be checked for 6SN1145-1BA02-0CA2?

6SN1145-1BA02-0CA2 requires the mains contactor with break contact to be verified against the installed wiring.

Can another 36/47 kW SIMODRIVE module automatically replace 6SN1145-1BA02-0CA2?

No. The complete 6SN1145-1BA02-0CA2 suffix, control version, cooling arrangement, connectors and lifecycle status must all match.

Which earlier article is related to 6SN1145-1BA02-0CA2?

6SN1145-1BA02-0CA2 follows 6SN1145-1BA02-0CA1, but the exact revision and interface details must be checked before exchange.

How should 6SN1145-1BA02-0CA2 be commissioned after exchange?

After fitting 6SN1145-1BA02-0CA2, verify precharge, DC-link voltage, regenerative operation, protective circuits and machine safety functions before production use.

You May Also Like