Home>PLC>Siemens A5F00133580-004 SINAMICS DCM CUD Control Board

Hot Categories

Siemens A5F00133580-004 SINAMICS DCM CUD Control Board

Siemens A5F00133580-004 SINAMICS DCM CUD Control Board

Item NO.: 3788587

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens A5F00133580-004 SINAMICS DCM CUD Control Board
  • Item NO.3788587
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-10-11
SINAMICS DCM | 6RA80 CONTROL UNIT | -004 REVISION

Siemens A5F00133580-004 SINAMICS DCM CUD Control Board

A revision-controlled central control board used inside the documented SINAMICS DCM converter assembly.

BrandSiemens
ModelA5F00133580-004
Product TypeSINAMICS DCM CUD Control Board, Revision -004
01

Overview

A5F00133580-004 is a Siemens component-level identifier associated with the CUD control board in the SINAMICS DCM 6RA80 drive platform. The board participates in converter control, drive I/O, communications and the commissioned parameter set.

A5F00133580-004 is not selected as a stand-alone PLC card. The complete 6RA80 converter MLFB, power section, installed option boards, connector layout and -004 board identity must remain linked throughout procurement and service.

02

Specs

Manufacturer Siemens
Component Identifier A5F00133580-004
Platform SINAMICS DCM
Host Converter Family 6RA80 DC drive
Component Class CUD central control board
Revision -004
System Role Converter control, signal processing, I/O and communications within the matched drive
Configuration Basis Commissioned SINAMICS DCM parameter set and drive project
Host Identity Required Complete 6RA80 MLFB, serial number and power-section data
Interface Record All plugs, option boards and communication connections must be photographed
Service Handling De-energized cabinet work with discharge verification and ESD control
Substitution Boundary No alternate A5F revision should be used without a documented Siemens service relationship
Acceptance Basis Diagnostics, parameter restoration, communications and controlled motor test
03

Features

01

Keeps the exact -004 board revision visible in the service record.

02

Coordinates the converter control functions assigned to the CUD assembly.

03

Retains the relationship between the board, 6RA80 power section and drive project.

04

Supports disciplined connector, option-board and firmware comparison before exchange.

04

Applications

  • Maintenance of installed SINAMICS DCM converters in DC motor and process-drive service.
  • Drive repair where diagnostics isolate the central control assembly rather than the power section.
  • Revision-controlled replacement requiring the original parameter and communication configuration.
05

Lifecycle

  • Create a full drive backup and capture parameters, telegrams, option-board settings and fault history.
  • Record the A5F00133580-004 label together with the complete 6RA80 nameplate and every plug position.
  • Verify cabinet isolation, DC-link discharge and ESD controls before accessing the board.
  • After installation, restore only the approved project and complete diagnostics, I/O, network, motor-direction and controlled-load tests.
06

FAQ

Can A5F00133580-004 be quoted accurately from the board number alone?

The board number identifies the requested revision, but the host 6RA80 MLFB, power section, option boards and connector photographs are needed to prevent a system-level mismatch.

What data loss risk should be addressed before removing A5F00133580-004?

The commissioned drive parameters, communication setup, technology functions and fault history must be archived before power is removed.

When is a different CUD revision an acceptable alternative to A5F00133580-004?

Only when a documented Siemens service relationship covers the installed converter, required firmware, options and parameter migration.

What test separates an A5F00133580-004 board fault from a power-section fault?

Use the converter diagnostics, supply checks, connector inspection and approved static tests before exchanging the board; uncontrolled live probing is not an acceptance method.

What should the final A5F00133580-004 commissioning report contain?

Record restored software and parameters, communication health, I/O checks, motor direction, current and field behavior, alarms and the controlled-load result.

You May Also Like