Home>PLC>Siemens C98043-A7004-L1 SIMOREG DC-MASTER Field Supply Board

Hot Categories

Siemens C98043-A7004-L1 SIMOREG DC-MASTER Field Supply Board

Siemens C98043-A7004-L1 SIMOREG DC-MASTER Field Supply Board

Item NO.: 3813370

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens C98043-A7004-L1 SIMOREG DC-MASTER Field Supply Board
  • Item NO.3813370
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-10-29
Siemens C98043-A7004-L1 SIMOREG DC-MASTER Field Supply Board
SIMOREG DC-MASTERPRODUCT RECORD

FIELD CURRENT SUPPLY · L1 HARDWARE IDENTITY · SERVICE ADJUSTMENT

Siemens C98043-A7004-L1 SIMOREG DC-MASTER Field Supply Board

A SIMOREG field-supply board whose L1 identity, host rating and post-replacement field-current offset adjustment must remain controlled.

Module numberA7004
ExecutionL1
Post-service stepP051 = 22
01
PRODUCT CONTEXT

Overview

C98043-A7004-L1 is Siemens field supply board A7004 in the L1 execution for the SIMOREG DC-MASTER platform. Siemens service guidance requires the replacement module number to match through the L number.

After an A7004 field module is replaced, Siemens specifies offset adjustment with P051 = 22 to set the zero point of the field-current actual-value sensing. All drive inputs, outputs and the electronics supply must be de-energized before module replacement.

02
CONTROLLED DATA

Specifications

Manufacturer
Siemens
Exact model
C98043-A7004-L1
Platform
SIMOREG DC-MASTER
Module function
Field supply board
Module number
C98043-A7004
L execution
L1
Replacement identity rule
Match through the L number
Required adjustment
P051 = 22 after replacement
Isolation requirement
De-energize I/O and electronics supply
Acceptance focus
Field-current sensing zero point
03
FUNCTIONAL PROFILE

Features

A

Field-current supply role

Belongs to the converter field circuit rather than the armature-control signal path.

B

L1 execution traceability

The L number remains a mandatory comparison point during module exchange.

C

Documented offset procedure

A specific Siemens adjustment restores the field-current sensing zero point.

D

Drive-level safety boundary

Replacement begins only after every relevant supply and I/O path is de-energized.

04
FIELD USE

Applications

SIMOREG field-circuit maintenance

Restoring the installed field-supply function in a documented DC drive.

Controlled board replacement

Matching the A7004-L1 identity before moving connectors or firing-circuit links.

Service acceptance

Completing the Siemens offset procedure and verifying stable field-current behavior.

05
SERVICE DISCIPLINE

Lifecycle

01

Prepare

Back up parameters, identify every connector and de-energize I/O plus electronics power.

02

Replace

Compare the old and new item numbers through L1 and transfer connections under the approved procedure.

03

Adjust

Run P051 = 22, then document field-current zero, response, alarms and converter operation.

06
CUSTOMER QUESTIONS

FAQ

Q01

What evidence should accompany a C98043-A7004-L1 request?

+

Provide the full module label, converter MLFB and serial number, field rating, connector photographs and parameter backup.

Q02

Can C98043-A7004-L2 replace C98043-A7004-L1 because the base number matches?

+

No automatic substitution is established; Siemens requires the item number to match through the L number.

Q03

Which adjustment follows a C98043-A7004-L1 replacement?

+

Siemens specifies P051 = 22 to adjust the zero point of field-current actual-value sensing.

Q04

What must be de-energized before removing C98043-A7004-L1?

+

All drive inputs and outputs, including the electronics voltage supply, must be de-energized.

Q05

What proves C98043-A7004-L1 is ready for operation?

+

Retain the L1 label match, completed offset adjustment, stable field current, clean diagnostics and successful drive tests.

IndustryParts industrial automation support
INDUSTRIAL PARTS SUPPORT

About IndustryParts

https://www.industryparts.com/

Exact identity before quotation

IndustryParts prepares C98043-A7004-L1 enquiries around the complete manufacturer label, requested quantity and destination. For controlled replacements, include the host-system record, field photographs and configuration evidence that apply to this exact execution.

Complete labelRevision retainedApplication evidence
ENQUIRY INFORMATION

Send the complete C98043-A7004-L1 label, requested quantity and destination.

You May Also Like