SIMOREG DC-MASTER · EXACT ARTICLE CONTROL · INDUSTRIAL AUTOMATION

Siemens C98043-A7010-L1 SIMOREG DC-MASTER Field Supply Module

The A7010-L1 field-supply module for the 15 A armature and 3 A field-current SIMOREG DC-MASTER hardware class.

01
PRODUCT CONTEXT

Product Overview

C98043-A7010-L1 is the L1 hardware execution of the C98043-A7010 field-supply module used in SIMOREG DC-MASTER converters. The submitted model does not include a trailing version field.

Siemens associates A7010-L1 with the 15 A armature-current class, 3 A rated field current and 0R1 values for both R1 and R2. The L2 execution belongs to a different 30 A / 5 A class.

Exchange guidance requires the board number to match through the L number. After replacing an A7010 field module, the field-current zero point must be adjusted with the documented P051 procedure.

02
PERFORMANCE RECORD

Performance

OPERATING ROLE 01

Form the field-supply bridge

The module carries the documented field-current path for the matched converter class.

OPERATING ROLE 02

Define the current class through L1

The L number prevents the 15 A / 3 A module from being confused with the higher-current L2 hardware.

OPERATING ROLE 03

Use host-specific wiring

Gate leads, connector positions and converter terminals remain governed by the installed 6RA70 hardware record.

03
CONTROLLED DATA

Technical Details

Manufacturer Siemens Exact model C98043-A7010-L1
Board family C98043-A7010 L number L1
Host platform SIMOREG DC-MASTER / 6RA70 Rated armature current class 15 A
Rated field current 3 A R1 0R1
R2 0R1 Post-exchange action Field-current offset adjustment with P051 = 22
Submitted version field Not included

About IndustryParts

https://www.industryparts.com/

No unverified version is added to the submitted label

IndustryParts keeps the exact L1 identity, host converter and field-adjustment evidence together so the quotation stays within the installed hardware class.

  • •Exact submitted model retained
  • •Installed-system evidence reviewed
  • •Requested quantity linked to the enquiry
IndustryParts industrial automation support
04
SYSTEM PATH

System Integration

STEP 01

Remove all converter power

De-energize inputs, outputs and electronics supply before accessing the module.

STEP 02

Verify the L number

Match C98043-A7010-L1 on the installed board rather than selecting by family number alone.

STEP 03

Capture converter context

Retain the 6RA70 order number, parameters, field wiring and connector photographs.

STEP 04

Adjust the field-current zero

Run P051 = 22 and verify field behavior through the approved commissioning test.

05
APPLICATION FIT

Applications

SIMOREG field-supply service

Maintaining the documented 15 A / 3 A field module in an installed 6RA70 converter.

L-number-controlled replacement

Preventing a visually similar A7010-L2 module from entering an L1 installation.

Converter maintenance records

Keeping the exact board, host, parameter and adjustment evidence together.

06
CUSTOMER QUESTIONS

FAQ

Q01

Should a trailing version be added to C98043-A7010-L1 when ordering?

No. Quote the complete installed label exactly; the submitted identity ends at L1 and no unverified version should be invented.

Q02

Can C98043-A7010-L1-5 be treated as identical to C98043-A7010-L1 without checking the label?

Siemens handles the version field separately from the mandatory L-number match, but the installed and proposed labels should still be compared and recorded before supply.

Q03

What converter evidence should accompany C98043-A7010-L1?

Send the full 6RA70 order number, field-current rating, old board label, connector photographs and parameter archive.

Q04

Why is P051 = 22 required after replacing C98043-A7010-L1?

It performs the documented zero-point adjustment for the field-current actual-value path after an A7010 field-module exchange.

Q05

What closes a C98043-A7010-L1 service record?

Correct L1 identity, secure wiring, completed offset adjustment, stable field-current feedback and passed drive tests provide acceptance evidence.