Home>PLC>Siemens C98043-A7010-L2 SIMOREG DC-MASTER Field-Supply Power-Section Board

Hot Categories

Siemens C98043-A7010-L2 SIMOREG DC-MASTER Field-Supply Power-Section Board

Siemens C98043-A7010-L2 SIMOREG DC-MASTER Field-Supply Power-Section Board

Item NO.: 3818582

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens C98043-A7010-L2 SIMOREG DC-MASTER Field-Supply Power-Section Board
  • Item NO.3818582
  • Weight0.5000 kg = 1.1023 lb = 17.6370 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-11-03
SIMOREG DC-MASTER · EXACT ARTICLE CONTROL · INDUSTRIAL AUTOMATION

Siemens C98043-A7010-L2 SIMOREG DC-MASTER Field-Supply Power-Section Board

The L2 execution of the SIMOREG DC-MASTER field-supply power section for the documented 30 A device class.

01
PRODUCT CONTEXT

Key Information

C98043-A7010-L2 is the L2 execution of the C98043-A7010 field-supply power-section board used in the 15 A and 30 A SIMOREG DC-MASTER device range.

Siemens assigns the L2 board to the 30 A armature-current and 5 A field-current execution. The board carries field power wiring and snubber functions, gate-pulse transformers, field-current sensing and field-line-voltage measurement.

The L number is a compatibility boundary. A replacement record should preserve the complete board label and the host 6RA70 order number.

02
OPERATING ROLE

Functions

01

Drive the field power section

Provides the documented power and trigger path for the field supply.

02

Measure field current

Uses the board sensing path required by the field-current control system.

03

Synchronize field gating

Derives the field-gating synchronization from the measured field line voltage.

04

Maintain protection evidence

Retains snubber, fuse-monitoring and board-identity information within the host unit record.

03
CONTROLLED DATA

Specifications

Manufacturer Siemens Exact model C98043-A7010-L2
Base board C98043-A7010 Execution L2
Product role Field-supply power-section board Device armature class 30 A
Field-current class 5 A Host platform SIMOREG DC-MASTER / 6RA70
Replacement boundary Board identity through the L number
04
INSTALLATION PATH

Installation

STEP 01

De-energize

Isolate all 6RA70 inputs, outputs and electronic power supplies before opening the unit.

STEP 02

Capture

Photograph the board label, host MLFB, connectors and conductor positions.

STEP 03

Replace

Match the C98043-A7010-L2 identity before transferring connections.

STEP 04

Adjust

After field-board exchange, perform the documented field-current offset calibration and controlled startup.

05
SERVICE DISCIPLINE

Lifecycle

L-number control
The replacement board number must match through L2; an execution-state suffix after that boundary is handled separately.
Calibration record
Retain the field-current offset adjustment result with the service order.
Host traceability
Keep the 6RA70 order and serial details with the board identity.

About IndustryParts

https://www.industryparts.com/

Field-board supply begins with the host-unit and L-number record

IndustryParts keeps the L2 label, host drive identity, connection evidence and requested quantity together for spare review.

  • •Exact submitted model retained
  • •Installed-system evidence reviewed
  • •Requested quantity linked to the enquiry
IndustryParts industrial automation support
07
CUSTOMER QUESTIONS

FAQ

Q01

What host data should accompany a C98043-A7010-L2 quotation?

Provide the complete 6RA70 MLFB, serial number, board label, connector photographs and requested quantity.

Q02

Can C98043-A7010-L1 replace C98043-A7010-L2?

No. Siemens assigns L1 and L2 to different device and field-current classes, so the L number must match.

Q03

What service step follows a C98043-A7010-L2 exchange?

Siemens requires the documented field-current offset calibration after replacing an A7010 field board.

Q04

Why is the full C98043-A7010-L2 label important?

It preserves the board family and L2 compatibility boundary instead of reducing selection to the A7010 base number.

Q05

What safety condition applies before handling C98043-A7010-L2?

All inputs, outputs and the electronics supply of the 6RA70 must be voltage-free under the approved procedure.

ENQUIRY INFORMATION

Request a model-specific quotation

Send the complete C98043-A7010-L2 label, requested quantity, delivery destination and installed-system context.

You May Also Like