WOODWARD DIGITAL OVERSPEED PROTECTION · EXACT ARTICLE CONTROL · INDUSTRIAL AUTOMATION

Woodward ProTech 203 Electronic Two-out-of-Three Overspeed Protection System

A three-channel digital overspeed trip system using independent speed-sensing units and a hardware two-out-of-three voting arrangement.

01
PRODUCT CONTEXT

Key Information

PROTECH 203 is Woodward’s electronic overspeed protection system for prime movers. Three identical and independent speed-sensing units monitor three magnetic-pickup signals and calculate speed separately.

The three trip-relay paths are arranged for a two-out-of-three hardware vote. A single failed unit can therefore be isolated and replaced while the remaining system continues to provide the intended voting function under the approved procedure.

The family includes different supply-voltage and trip-relay philosophies. A complete enquiry must identify the installed part number and whether the system is de-energize-to-trip or energize-to-trip; the family name alone does not define that selection.

02
OPERATING ROLE

Functions

01

Monitor three independent speeds

Each unit receives its own magnetic-pickup signal and presents speed and status information on its front panel.

02

Vote the trip decision

Hardware two-out-of-three relay voting separates a single-channel fault from the final overspeed trip output.

03

Support on-line testing

The design provides on-line test functions for verifying individual speed channels without treating the test as a complete turbine-system proof.

04

Permit modular unit service

One failed sensing unit can be replaced while the system is operating when the approved site procedure and remaining protection state permit it.

03
CONTROLLED DATA

Specifications

Manufacturer Woodward Exact model PROTECH 203
Product type Digital overspeed trip system Speed channels 3 independent units
Speed sensors Three magnetic pickups Trip logic Hardware two-out-of-three vote
Available trip philosophies De-energize-to-trip or energize-to-trip Front indication Digital speed displays and status LEDs
Service feature Individual unit replacement while operating Configuration boundary Part number defines supply and trip execution

About IndustryParts

https://www.industryparts.com/

Overspeed quotations start with the complete system execution

IndustryParts keeps the system part number, trip philosophy, supply record and requested quantity together before proposing ProTech 203 hardware.

  • •Exact submitted model retained
  • •Installed-system evidence reviewed
  • •Requested quantity linked to the enquiry
IndustryParts industrial automation support
04
INSTALLATION PATH

Installation

STEP 01

Identify the exact system part number

Record the complete Woodward part number and all three unit labels before selecting replacement hardware.

STEP 02

Capture protection settings

Archive overspeed setpoints, MPU characteristics, relay logic and turbine trip interfaces.

STEP 03

Plan channel-by-channel work

Keep two verified protection channels available and follow the approved bypass and test procedure.

STEP 04

Complete the plant proof test

After service, verify all three speed channels, voting behavior, trip relays and the turbine-system shutdown path.

05
SERVICE DISCIPLINE

Lifecycle

Family-level page
Use this page to identify the ProTech 203 architecture, not to infer the supply voltage of an unlabelled unit.
Trip philosophy custody
Keep energize/de-energize selection with the exact system part number and site safety analysis.
Proof-test record
Individual on-line tests do not replace the approved full overspeed protection proof test.
07
CUSTOMER QUESTIONS

FAQ

Q01

Why is the complete part number required for a PROTECH 203 quotation?

The family was supplied with different input-power and trip-relay executions, so the ProTech 203 name alone cannot define the correct spare.

Q02

Can an energize-to-trip unit replace a de-energize-to-trip PROTECH 203 unit?

No direct substitution should be made because the relay philosophy changes the behavior during power loss and must match the approved protection design.

Q03

What magnetic-pickup evidence should accompany PROTECH 203?

Provide all three MPU models, tooth count, expected speed range, wiring records and the installed gap information used by the site procedure.

Q04

How is one PROTECH 203 channel serviced without defeating protection?

Use the approved channel bypass and on-line test procedure while confirming the remaining two channels and trip path stay available.

Q05

What closes a PROTECH 203 service record?

Verified speed indication on all channels, correct two-out-of-three voting, proven relay outputs and the completed turbine trip test provide acceptance evidence.

ENQUIRY INFORMATION