Thirty-two output points
Provides a concentrated mechanical-relay termination field for wet-contact output circuits.
Warranty: 1 year
Condition : brand new in factory sealed box
Email: sales@mvme.cn
Chat online: +86 18030175807
A basic 19-inch rack-mount relay board providing thirty-two wet-contact output points through M4 screw terminals.
ARM55W-000 is Yokogawa ARM55W in the -000 execution. The model code identifies thirty-two wet-contact outputs with M4 terminals, a 19-inch rack-mount construction and the basic hardware type.
The relay board is a field-interface accessory used with documented Yokogawa I/O arrangements. Cable routing, output commoning, field supply and the connected module must be checked from the installed drawings rather than inferred from another ARM55 variant.
Yokogawa
ARM55W-000
ARM55W
Wet-contact outputs
32
M4 screw terminals
19-inch rack mountable
Basic type
/BR4 when specified separately
482.6 mm overall rack face
Field supply and cable schedule required
Provides a concentrated mechanical-relay termination field for wet-contact output circuits.
Fits the documented 19-inch interface-board mounting arrangement.
Uses screw-terminal connections that require a retained conductor and torque record.
Keeps the wet-contact ARM55W identity distinct from dry-contact and switched variants.
Interfacing a documented Yokogawa digital-output path with field wiring and supply.
Replacing a board while preserving cable grouping, terminal numbering and grounding.
Rebuilding an accurate point-to-terminal record for an installed relay assembly.
Photograph the full ARM55W-000 label and record every terminal, field supply, common and connected I/O cable.
Isolate field energy and reproduce the approved rack position, terminal assignment and conductor torque.
Prove each commanded output and safe state, then verify the corresponding control-system diagnostics.
Provide the complete -000 label, rack position, connected I/O module, field voltage, cable schedule and requested quantity.
No direct substitution should be assumed because ARM55D is documented as a dry-contact output board, while ARM55W-000 uses wet-contact outputs.
It retains the published 19-inch rack-mount and basic-type selections for the ARM55W family.
The thirty-two M4 terminals carry the installed output and field-supply arrangement that must be reproduced exactly.
Correct terminal mapping, conductor checks, output proving and normal control-system diagnostics are required.
IndustryParts prepares ARM55W-000 enquiries around the complete manufacturer label, requested quantity and installed-system evidence. Share the application record that distinguishes this execution before a supply proposal is prepared.
Send the complete ARM55W-000 label, requested quantity and delivery destination.