Home>DCS>Yokogawa CP471-01 CENTUM VP Processor Module

Hot Categories

Yokogawa CP471-01 CENTUM VP Processor Module

Yokogawa CP471-01 CENTUM VP Processor Module

Item NO.: 3790104

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameYokogawa CP471-01 CENTUM VP Processor Module
  • Item NO.3790104
  • Weight0.6000 kg = 1.3228 lb = 21.1644 oz
  • CategoryDCS
  • BrandYOKOGAWA
  • Creation Time2026-10-12
CENTUM VP | PROCESSOR MODULE | ISA STANDARD G3

Yokogawa CP471-01 CENTUM VP Processor Module

A no-explosion-protection CP471 processor execution with the ISA Standard G3 option for supported CENTUM field control units.

BrandYokogawa
ModelCP471-01
Product TypeCENTUM VP Processor Module with ISA Standard G3 Option
01

Overview

CP471-01 is a Yokogawa processor module for CENTUM field control units. Its first suffix digit specifies no explosion protection, and the second digit selects the ISA Standard G3 option.

Two CP471 modules may be installed in a dual-redundant configuration on a duplexed field control unit. Compatibility depends on the FCU model code, CENTUM VP release and the associated EC401 style where that bus coupler is used.

02

Specs

Manufacturer Yokogawa Electric Corporation
Model CP471-01
Product Type Processor module
Control Platform CENTUM VP field control station
Explosion-Protection Suffix 0; no explosion protection
Environmental Option Suffix 1; ISA Standard G3 option
Redundancy Two modules supported in dual-redundant configuration on a duplexed FCU
Software Baseline CENTUM VP R5.01 or later Control Function for FCS
Patch Requirement Supporting patch required for listed releases R5.01 through R5.04 and R6.01 through R6.04
Supported R5 FCU Families AFV30S/D and AFV40S/D, subject to the exact FCU code
Supported R6 Families AFV30S/D, AFV40S/D, A2FV50S/D, A2FV70S/D and A2BE1D subject to suffix rules
ESB Bus Coupler EC401 style code S3 or later when combined
Migration Context Existing CP461 can be replaced by CP471 only under the documented service conditions
03

Features

01

Processor module designed specifically for supported CENTUM field control units.

02

ISA Standard G3 execution supports the corresponding environmental requirement.

03

Dual-redundant deployment is available in the documented duplexed FCU arrangement.

04

Manufacturer-defined software and chassis rules control CP461 migration.

04

Applications

  • CENTUM VP field control stations requiring the CP471-01 environmental execution.
  • Duplexed FCS maintenance where processor redundancy must be preserved.
  • Authorized upgrades from CP461 after FCU, software and bus-coupler qualification.
05

Lifecycle

  • Record the complete FCU code, CENTUM release, patches, EC401 style and redundancy state.
  • Back up the control database and preserve network, time and diagnostic records.
  • Follow Yokogawa service requirements for CP461-to-CP471 migration rather than treating it as an unrestricted user exchange.
  • After work, verify both processor states, synchronization, FCS communications, I/O health and application control.
06

FAQ

Why is the complete FCU code required when quoting CP471-01?

The applicable processor suffix depends on the field control unit family and its own model-code positions.

Can CP471-01 replace CP461 without a migration review?

No. Yokogawa documents specific FCU, software, patch and authorized-service conditions for the migration.

What does the 01 suffix mean on CP471-01?

It identifies no explosion protection together with the ISA Standard G3 option.

Which software evidence should accompany CP471-01?

Provide the CENTUM VP release, installed support patches, FCS control-function version and database backup.

What should be tested after installing CP471-01 in a duplexed FCU?

Verify processor synchronization, switchover readiness, Vnet/IP health, I/O status, diagnostics and application control.

You May Also Like