Home>DCS>Yokogawa F3LC31-2F Modbus Interface Module

Hot Categories

Yokogawa F3LC31-2F Modbus Interface Module

Yokogawa F3LC31-2F Modbus Interface Module

Item NO.: 3794816

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameYokogawa F3LC31-2F Modbus Interface Module
  • Item NO.3794816
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandYOKOGAWA
  • Creation Time2026-10-15
FA-M3 / MODBUS RTU & ASCII / ISOLATED PORT

Yokogawa F3LC31-2F Modbus Interface Module

A single-port isolated RS-422/RS-485 communications module supporting Modbus RTU and Modbus ASCII master or slave operation.

ManufacturerYokogawa
Exact modelF3LC31-2F
Product typeFA-M3 Modbus Interface Module
01

Product Profile

F3LC31-2F is the Yokogawa FA-M3 Modbus interface module. It provides one isolated port conforming to EIA RS-422-A / RS-485.

The module supports both Modbus RTU and Modbus ASCII and can operate as a master communicating with third-party slaves or as a slave responding to an external master.

Two-wire and four-wire arrangements are supported with half-duplex transmission and shielded twisted-pair cabling.

02

Technical Data

Manufacturer Yokogawa
Exact model F3LC31-2F
System family FA-M3
Interface EIA RS-422-A / RS-485
Ports 1 isolated port
Protocols Modbus RTU and Modbus ASCII
Operating roles Master or slave
Transmission mode Half-duplex, 4-wire or 2-wire
Transmission rates 300, 600, 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57.6k and 115.2 kbps
Maximum distance 1200 m total
Transmission medium Shielded twisted pair, AWG20 to AWG16
Terminal block 6-point, M3.5 screws
External dimensions 28.9 × 100 × 83.2 mm
03

System Role

01

Links an FA-M3 controller to Modbus-compatible instruments and controllers over RS-422/RS-485.

02

Acts as a Modbus master for polling market-standard slave devices.

03

Acts as a Modbus slave for integration under another vendor’s master controller.

04

Provides an isolated serial path for electrically separated industrial communications.

About IndustryParts

https://www.industryparts.com/

Serial-network settings remain part of the record

IndustryParts prepares F3LC31-2F quotations with the wiring mode, protocol format and station map so the replacement can be commissioned predictably.

  • RTU/ASCII mode recorded
  • Two-/four-wire topology checked
  • Station map requested
IndustryParts office verification
04

Compatibility

  • No restriction is specified on the FA-M3 CPU module type used with F3LC31-2F.
  • Use the correct two-wire or four-wire terminal arrangement from Yokogawa documentation.
  • For two-wire operation, short SDA to RDA and SDB to RDB at the terminal block as documented.
  • Confirm baud rate, RTU/ASCII format, station address, parity and timeout settings at both ends.
05

Applications

  • FA-M3 integration with drives, meters, analyzers and remote I/O using Modbus.
  • Brownfield serial-network expansion where an isolated RS-485 port is required.
  • Gateway duties between an FA-M3 application and a third-party Modbus master or slave.
06

FAQ

Q01Can F3LC31-2F operate as both Modbus master and slave?

Yes. Yokogawa documents both roles, but the selected mode and message handling must be configured consistently with the application.

Q02What network record should accompany an F3LC31-2F enquiry?

Provide CPU and base-unit models, slot, wiring type, baud rate, RTU or ASCII selection, parity, station map, cable length and current diagnostics.

Q03What changes when F3LC31-2F is wired for two-wire RS-485?

SDA must be connected to RDA and SDB to RDB at the module terminal block; confirm bias, termination and grounding for the entire network.

Q04How should intermittent F3LC31-2F communication be investigated?

Review shielding, termination, duplicate addresses, baud and parity settings, timeout design, cable length and error counters before replacing the module.

Q05What proves an F3LC31-2F replacement is ready?

Confirm the exact model, restored parameters, stable communications with every required station, clean error statistics and successful application message testing.

Enquiry Information

Send the complete F3LC31-2F label, quantity and destination for an exact enquiry record.

WHATSAPP / PHONE+86 18030175807

You May Also Like