Home>DCS>Yokogawa FLXA202-D-C-D-AB-P1-NN-A-N-LA-N-NN 2-Wire Analyzer

Hot Categories

Yokogawa FLXA202-D-C-D-AB-P1-NN-A-N-LA-N-NN 2-Wire Analyzer

Yokogawa FLXA202-D-C-D-AB-P1-NN-A-N-LA-N-NN 2-Wire Analyzer

Item NO.: 3788804

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameYokogawa FLXA202-D-C-D-AB-P1-NN-A-N-LA-N-NN 2-Wire Analyzer
  • Item NO.3788804
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandYOKOGAWA
  • Creation Time2026-10-12
YOKOGAWA FLEXA | SINGLE pH/ORP INPUT | HART OUTPUT

Yokogawa FLXA202-D-C-D-AB-P1-NN-A-N-LA-N-NN 2-Wire Analyzer

A single-input pH/ORP FLXA202 with epoxy-coated aluminum housing, anti-glare display and 4–20 mA HART output.

BrandYokogawa
ModelFLXA202-D-C-D-AB-P1-NN-A-N-LA-N-NN
Product TypeFLXA202 2-Wire pH/ORP Analyzer
01

Technical Summary

FLXA202-D-C-D-AB-P1-NN-A-N-LA-N-NN is a Yokogawa FLEXA 2-wire analyzer configured for one analog pH/ORP input. The suffix identifies an epoxy-coated cast-aluminum housing, anti-glare LCD and general-purpose CE/RCM configuration.

The analyzer provides loop-powered 4–20 mA communication with HART, touchscreen operation, quick setup, sensor wellness information, calibration support and an event/diagnostic logbook.

02

Specifications

Manufacturer Yokogawa Electric Corporation
Model FLXA202-D-C-D-AB-P1-NN-A-N-LA-N-NN
Product Family FLEXA FLXA202
Analyzer Type 2-wire analyzer
Housing Cast aluminum with epoxy coating
Display Anti-glare LCD with touch operation
Approval Type General purpose for CE and RCM
First Input Analog pH/ORP
Second Input Not fitted
Output 4–20 mA with HART
Language Set English plus 11 additional display languages
Country Code Global except Japan
03

Features

  • Automatically recognizes the installed sensor module and prepares the applicable setup menus.
  • Provides guided quick setup for date, language, sensor configuration and output.
  • Supports temperature compensation, calibration functions and sensor-health indication.
  • Maintains event and diagnostic records that assist planned analyzer maintenance.
04

Compatibility

  • Use an approved analog pH/ORP sensor and match its temperature element and cable arrangement.
  • Confirm the loop supply, load, HART interface and hazardous-area classification of the installation.
  • Do not replace the -C epoxy-coated housing or -AB approval suffix with another version without reviewing the environment and certificates.
  • The -NN second-input code describes a single-input build; dual-input functions require a different complete order code.
05

Replacement

  • Export analyzer settings and record the sensor type, temperature element, calibration history and HART tag.
  • Inspect enclosure seals, cable glands, earth connection and sensor wiring before installing the replacement.
  • Restore the approved range, damping, temperature compensation, alarm status and current-output mapping.
  • Complete buffer calibration, loop-current verification and host-system indication checks.
06

FAQ

FLXA202-D-C-D-AB-P1-NN-A-N-LA-N-NN: Which sensor details should accompany a quotation?

Provide the pH/ORP sensor model, temperature element, cable or junction arrangement, wetted process conditions and current analyzer label.

FLXA202-D-C-D-AB-P1-NN-A-N-LA-N-NN: Can a dual-input FLXA202 replace this single-input configuration directly?

A dual-input build changes the hardware and setup scope; confirm the second module, sensor pairing and output strategy before substitution.

FLXA202-D-C-D-AB-P1-NN-A-N-LA-N-NN: What is the purchasing consequence of the -C and -AB suffixes?

They control the enclosure coating and approval configuration, so both must be checked against the installation environment and project documentation.

FLXA202-D-C-D-AB-P1-NN-A-N-LA-N-NN: What should be verified before reconnecting the HART loop?

Confirm polarity, available loop voltage, total load, barrier or isolator data and the control-system scaling.

FLXA202-D-C-D-AB-P1-NN-A-N-LA-N-NN: What acceptance evidence is useful after commissioning?

Retain buffer results, slope and zero data, temperature agreement, loop-current tests, HART tag confirmation and final configuration backup.

You May Also Like