Home>DCS>Yokogawa FLXA202-D-D-D-CD-P1-NN-A-N-LA-N-NN 2-Wire Analyzer

Hot Categories

Yokogawa FLXA202-D-D-D-CD-P1-NN-A-N-LA-N-NN 2-Wire Analyzer

Yokogawa FLXA202-D-D-D-CD-P1-NN-A-N-LA-N-NN 2-Wire Analyzer

Item NO.: 3788824

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameYokogawa FLXA202-D-D-D-CD-P1-NN-A-N-LA-N-NN 2-Wire Analyzer
  • Item NO.3788824
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandYOKOGAWA
  • Creation Time2026-10-12
YOKOGAWA FLEXA | HIGH ANTI-CORROSION HOUSING | US/CANADA INTRINSIC SAFETY

Yokogawa FLXA202-D-D-D-CD-P1-NN-A-N-LA-N-NN 2-Wire Analyzer

A single-input pH/ORP FLXA202 with high anti-corrosion housing and intrinsically safe US/Canada configuration.

BrandYokogawa
ModelFLXA202-D-D-D-CD-P1-NN-A-N-LA-N-NN
Product TypeIntrinsically Safe FLXA202 2-Wire pH/ORP Analyzer
01

Product Identification

FLXA202-D-D-D-CD-P1-NN-A-N-LA-N-NN is a Yokogawa 2-wire pH/ORP analyzer with cast-aluminum high anti-corrosion coating. Its -CD type code identifies the intrinsically safe configuration for the United States and Canada.

This build has one analog pH/ORP input, no second sensor input and a 4–20 mA HART output. Hazardous-area installation must follow the applicable control drawing, entity parameters and enclosure conditions.

02

Engineering Data

Manufacturer Yokogawa Electric Corporation
Model FLXA202-D-D-D-CD-P1-NN-A-N-LA-N-NN
Product Family FLEXA FLXA202
Housing Cast aluminum with high anti-corrosion coating
Display Anti-glare LCD with touch operation
Protection Type Intrinsic safety for United States and Canada
Temperature Class T4 under the applicable approval conditions
First Input Analog pH/ORP
Second Input Not fitted
Output 4–20 mA with HART
Language Set English plus 11 additional display languages
Country Code Global except Japan
03

Functions

  • Performs loop-powered pH or ORP measurement with sensor calibration and temperature compensation.
  • Provides touchscreen configuration, quick setup, sensor wellness and diagnostic log functions.
  • Communicates the process value and device information through the configured HART current loop.
  • Uses a corrosion-resistant enclosure construction for demanding process environments.
04

Applications

  • pH or ORP measurement loops located in approved hazardous-area installations.
  • Chemical and water-treatment services requiring high anti-corrosion enclosure coating.
  • HART-integrated analytical loops with a compatible barrier or isolator.
  • Single-sensor replacement projects where the complete -CD approval configuration must be retained.
05

Lifecycle

  • Keep the complete model code, control drawing, barrier data and area classification together in the loop file.
  • Record sensor type, temperature element, calibration history, HART tag and output mapping.
  • Inspect coating, seals, cable entries and grounding during each planned maintenance interval.
  • Treat any approval, housing or sensor-module change as an engineered loop modification.
07

FAQ

FLXA202-D-D-D-CD-P1-NN-A-N-LA-N-NN: Which hazardous-area documents are needed before quotation?

Provide the area classification, installed control drawing, barrier or isolator model, entity parameters and cable-entry details.

FLXA202-D-D-D-CD-P1-NN-A-N-LA-N-NN: Can a general-purpose -AB analyzer replace this -CD version?

No direct substitution should be made because the intrinsic-safety approval and installation controls would change.

FLXA202-D-D-D-CD-P1-NN-A-N-LA-N-NN: What should be checked when retaining the existing pH/ORP sensor?

Confirm sensor approval, temperature element, cable system, entity compatibility and process-wetted suitability.

FLXA202-D-D-D-CD-P1-NN-A-N-LA-N-NN: How is the high anti-corrosion housing relevant to replacement?

Changing the housing coating can reduce suitability for the site atmosphere, so the environmental basis must be reviewed before accepting another suffix.

FLXA202-D-D-D-CD-P1-NN-A-N-LA-N-NN: Which tests should close the replacement work?

Complete calibration, temperature agreement, loop-current and HART checks, alarm verification and the site intrinsic-safety inspection record.