Combines pH measuring, reference and temperature functions in one wide-body assembly.
Product Overview
FU20-10-T1-NPT is a Yokogawa FU20 wide-body combination pH/ORP sensor. Its model code fixes the cable, temperature element and body style.
The 10 suffix denotes a 10 m integral cable; T1 denotes Pt1000; NPT denotes the PPS body with tapered thread and dome-shaped sensing end.
The dimensional drawing shows a 3/4-inch tapered process thread that fits a 3/4 NPT female connection.
Performance
Provides the Pt1000 signal used by the analyzer for compensation.
Uses the integral 10 m cable to avoid an intermediate connector at the sensor body.
Mounts through the specified tapered-thread process connection or an approved adapter.
Technical Details
| Manufacturer | Yokogawa |
|---|---|
| Exact model | FU20-10-T1-NPT |
| Sensor family | FU20 wide-body pH/ORP combination sensor |
| Cable length | 10 m integral cable |
| Temperature element | Pt1000 |
| Body style | PPS body, tapered thread, dome-shaped sensing end |
| Process connection | 3/4-inch tapered thread for 3/4 NPT female connection |
| Sensor body length | 150 mm |
| Maximum body diameter | Approximately 26 mm |
| Cable outside diameter | Approximately 6.5 mm |
| Available optional adapters for NPT/FSM/FTD family | 1-inch NPT or BSP adapters in SS316 or titanium, selected separately |
System Integration
- Confirm analyzer support for the FU20 electrode system and Pt1000 input.
- Verify chemical compatibility of the PPS body and all wetted sealing materials.
- Plan cable routing without cutting, extending or coiling against manufacturer guidance.
- Confirm the process fitting accepts the 3/4 NPT tapered-thread arrangement.
Applications
- Industrial pH or ORP measurement with compatible chemistry and mounting.
- Tank, pipe or flow assembly duties that suit a wide-body combination sensor.
- Replacement of the exact 10 m, Pt1000, NPT configuration.
About IndustryParts
https://www.industryparts.com/The suffix code defines the complete sensor assembly
IndustryParts retains the cable length, temperature element and NPT body code when preparing an FU20-10-T1-NPT enquiry.
- 10 m cable retained
- Pt1000 confirmed
- NPT process fit checked
FAQ
Q01What details should accompany an FU20-10-T1-NPT enquiry?
Send the full sensor code, analyzer model, process chemistry, range, temperature, pressure, fitting, cable route and required cleaning or adapter options.
Q02Can FU20-10-T1-NPT replace FU20-10-T2-NPT?
Not without analyzer review. T1 is Pt1000 and T2 is Pt100, so the temperature input and compensation configuration differ.
Q03How should a stored FU20-10-T1-NPT be evaluated?
Inspect the glass, reference junction, cable and thread, confirm wet-storage condition where applicable, then calibrate with fresh traceable buffers before service.
Q04What installation mistakes most often affect FU20-10-T1-NPT?
Incorrect thread engagement, trapped air, poor cable routing, unsuitable chemistry and an analyzer configured for the wrong temperature element can all compromise performance.
Q05What proves FU20-10-T1-NPT is ready after replacement?
Record exact model identity, leak-free mounting, stable Pt1000 reading, successful two-point pH calibration or approved ORP check and stable process response.
Recommended Models
| MSF-045 525 2 C-N-AAU | 6308 D40/D90X23 | ABB DO561 1TNE968902R2201 |
| Wago 750-301 | STEP-PS/1AC/12DC/5 2868583 | 1125WBN-10PKG |
| ABB 2CDG110042R0011 | 53.602.0E AC5360B.0Z | X20AO2622 |
| LK3023 | AP-101-11-2 | 1F83-71 2 |
| X20BM26 | MTN647593 | 140ACO13000 |
| WMG 4371944-125 | Danfoss MCD5-0428C-T5-G4X-00-CV2 175G5540 | 5T0001D000700F-000 |
| MPN 44-H 4.3-B 25.20-DK1TR | DLC-MASTER | MCE3 |
| 3IF050.6 | Siemens 1PH8165-1DF03-0CC1 | 6ES7422-1HH00-0AA0 |
| ABB 1SAZ211201R1031 | DRE90M4BE2 | AI354 |
| DDTC001 | 11-PKZ | EAMK-A-D32-44A/C |