Home>DCS>Yokogawa PH8ERP-05 KCl-Refillable pH Sensor, 5 m Cable Execution

Hot Categories

Yokogawa PH8ERP-05 KCl-Refillable pH Sensor, 5 m Cable Execution

Yokogawa PH8ERP-05 KCl-Refillable pH Sensor, 5 m Cable Execution

Item NO.: 3805349

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameYokogawa PH8ERP-05 KCl-Refillable pH Sensor, 5 m Cable Execution
  • Item NO.3805349
  • Weight0.3000 kg = 0.6614 lb = 10.5822 oz
  • CategoryDCS
  • BrandYOKOGAWA
  • Creation Time2026-10-23
REFILLABLE KCL REFERENCE · 5 M INTEGRAL CABLE

Yokogawa PH8ERP-05 KCl-Refillable pH Sensor, 5 m Cable Execution

A PH8ERP-family refillable pH sensor ordering execution in which the -05 field selects a 5 m integral cable.

01
PRODUCT CONTEXT

Technical Summary

Yokogawa PH8ERP-05 belongs to the PH8ERP KCl-refillable pH sensor family. In the ordering code, the -05 field identifies the 5 m cable execution.

The submitted string does not state the later ordering selections used for the solution-ground tip, measuring system, style and optional construction. Those positions remain part of the final sensor identity and must be taken from the complete installed label.

For service work, preserve the electrode assembly, cable routing and analyzer connection as one documented measurement chain rather than treating cable length as the only selection point.

02
ENGINEERING RECORD

Specifications

ManufacturerYokogawa
Exact submitted modelPH8ERP-05
Product familyPH8ERP
Sensor constructionKCl-refillable pH sensor
Cable code05
Cable length5 m
Identity boundaryComplete later suffix positions remain required for an exact replacement
03
CAPABILITY MAP

Features

01

Refillable reference design

The PH8ERP family uses a refillable KCl reference arrangement for maintained pH measurement service.

02

Integral cable selection

The 05 ordering field fixes the sensor cable at 5 m and must remain visible in the enquiry record.

03

Configuration-controlled tip

Solution-ground and measuring-system choices belong to the full ordering string and cannot be assumed from the cable field.

04

Chain-based maintenance

Sensor, cable, holder and connected analyzer information are retained together for troubleshooting and replacement.

INDUSTRIAL AUTOMATION SUPPLY SUPPORT

About IndustryParts

https://www.industryparts.com/

Exact-model handling for PH8ERP-05

IndustryParts keeps the complete PH8ERP-05 identity, requested quantity and installed-system evidence together so the proposed supply can be checked against the actual application before dispatch.

Complete label retained with the enquiry
Installed-system evidence reviewed before quotation
Exact requested quantity linked to the model record
IndustryParts industrial automation support team
04
SYSTEM BOUNDARIES

Compatibility

A

Complete ordering code

Compare the full sensor label, not only PH8ERP-05, before approving an interchangeable assembly.

B

Mechanical installation

Record holder style, insertion geometry, seals and cable-entry route from the installed point.

C

Measurement loop

Confirm analyzer input, temperature-compensation arrangement and every connected lead from the loop documentation.

05
SERVICE SEQUENCE

Replacement

STEP 1

Capture the installed identity

Photograph the entire label and record every ordering position that follows the 05 cable field.

STEP 2

Preserve the wet-end arrangement

Retain the approved holder, immersion or insertion geometry, seals and solution-ground construction.

STEP 3

Recommission the loop

Complete the required conditioning, calibration and process comparison before returning the pH point to control.

06
CUSTOMER DECISION SUPPORT

FAQ

Q01

Is PH8ERP-05 a complete ordering code for every installation?

Not necessarily. The 05 cable field is defined, but the full PH8ERP identity also uses later positions for the ground tip, measuring system, style and options. Supply the complete nameplate string.

Q02

What field evidence should accompany a PH8ERP-05 enquiry?

Provide clear sensor and analyzer labels, holder photographs, cable routing, process connection, temperature-compensation details and the current loop drawing.

Q03

Can a different PH8ERP cable length replace PH8ERP-05 without review?

No. Extra or reduced cable changes routing and termination conditions, and the remaining sensor construction must still match the installed measurement chain.

Q04

Which parts of the pH loop should be checked before removing PH8ERP-05?

Document the holder, seals, reference-electrolyte handling, solution-ground connection, analyzer terminals and any temperature element before isolation.

Q05

What closes a PH8ERP-05 replacement record?

Record the complete installed code, physical fit, leak inspection, stable calibration results and a credible process comparison after the sensor has conditioned.

You May Also Like