Home>DCS>Yokogawa SAI143-H63 16-Channel 4–20 mA HART Analog Input Module

Hot Categories

Yokogawa SAI143-H63 16-Channel 4–20 mA HART Analog Input Module

Yokogawa SAI143-H63 16-Channel 4–20 mA HART Analog Input Module

Item NO.: 3805370

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameYokogawa SAI143-H63 16-Channel 4–20 mA HART Analog Input Module
  • Item NO.3805370
  • Weight0.3000 kg = 0.6614 lb = 10.5822 oz
  • CategoryDCS
  • BrandYOKOGAWA
  • Creation Time2026-10-23
HART INPUT · SIGNAL-CABLE ADAPTER · ISA STANDARD G3

Yokogawa SAI143-H63 16-Channel 4–20 mA HART Analog Input Module

A 16-channel ProSafe-RS 4–20 mA HART input module using the H63 signal-cable-interface execution.

01
PRODUCT CONTEXT

Technical Summary

Yokogawa SAI143-H63 is an SAI143 analog input module for sixteen 4–20 mA channels with HART communication and module isolation.

The H63 execution identifies HART support, the signal cable interface adapter connection, no explosion-protection suffix and the ISA Standard G3 / −20 to +70 °C option.

This execution is planned around the Yokogawa-specific cable path rather than the pressure-clamp or MIL terminal form used by another SAI143 suffix. Cable identity and false-insertion prevention therefore belong in the spare record.

02
ENGINEERING RECORD

Specifications

ManufacturerYokogawa
Exact modelSAI143-H63
Product familySAI143
Input channels16
Signal4–20 mA
CommunicationHART
IsolationModule isolation
Termination executionSignal cable interface adapter
Explosion-protection selectionNone in the H63 code
Environmental optionISA Standard G3; −20 to +70 °C
Cable familyKS1 cable with SAI143 execution
03
CAPABILITY MAP

Features

01

HART-capable acquisition

Process current and HART communication share the approved SAI143 input path.

02

Adapter-based connection

The 6 termination digit selects the signal cable interface adapter rather than a direct terminal block.

03

G3 environmental execution

The final 3 position identifies the ISA Standard G3 and extended-temperature option.

04

Insertion-control option

Applicable systems can use the documented prevention-pin arrangement with the matching cable selection.

INDUSTRIAL AUTOMATION SUPPLY SUPPORT

About IndustryParts

https://www.industryparts.com/

Exact-model handling for SAI143-H63

IndustryParts keeps the complete SAI143-H63 identity, requested quantity and installed-system evidence together so the proposed supply can be checked against the actual application before dispatch.

Complete label retained with the enquiry
Installed-system evidence reviewed before quotation
Exact requested quantity linked to the model record
IndustryParts industrial automation support team
04
SYSTEM BOUNDARIES

Compatibility

A

Cable assembly

Match the exact KS1 cable suffix intended for SAI143 and document both ends before disconnection.

B

System slot

Confirm safety-node position, redundant or single configuration and the approved ProSafe-RS engineering record.

C

Channel definition

Preserve transmitter supply, loop polarity, HART use, range, alarms and bypass/interlock handling per point.

05
SERVICE SEQUENCE

Replacement

STEP 1

Trace the cable path

Record module, adapter and remote termination identities plus cable tags and prevention-pin arrangement.

STEP 2

Control the safety state

Apply the approved shutdown, bypass and proof-test procedure before disturbing any input circuit.

STEP 3

Validate every loop

Check current value, HART communication where used, diagnostics and the associated safety-function response.

06
CUSTOMER DECISION SUPPORT

FAQ

Q01

What distinguishes SAI143-H63 from SAI143-H53?

The H63 code uses the signal cable interface adapter path; H53 is the pressure-clamp or MIL-cable termination execution. They are not treated as the same wiring form.

Q02

Which cable record is essential for SAI143-H63?

Provide both connector labels, complete KS1 cable code, route, remote termination identity and any false-insertion-prevention details.

Q03

Can pressure-clamp options be added to SAI143-H63?

The H63 termination digit defines the signal-cable-interface path, so direct pressure-clamp or MIL options from the H5 execution should not be assumed.

Q04

What safety information should accompany a SAI143-H63 enquiry?

Include node and slot, single or redundant arrangement, loop list, HART use, cause-and-effect reference and approved maintenance state.

Q05

How should SAI143-H63 be returned to service?

Prove every affected current loop, diagnostics, HART path where used and final safety action under the site proof-test procedure.