Home>DCS>Yokogawa SAI143-S63 16-Channel Analog Input Module

Hot Categories

Yokogawa SAI143-S63 16-Channel Analog Input Module

Yokogawa SAI143-S63 16-Channel Analog Input Module

Item NO.: 3442008

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameYokogawa SAI143-S63 16-Channel Analog Input Module
  • Item NO.3442008
  • Weight0.3900 kg = 0.8598 lb = 13.7568 oz
  • CategoryDCS
  • BrandYOKOGAWA
  • Creation Time2025-11-13
ProSafe-RS / 4–20 mA / ISA Standard G3

Yokogawa SAI143-S63 16-Channel Analog Input Module

A standard, non-HART 16-channel current-input module with signal-cable adapter, Yokogawa-specific KS1 cabling and the S63 extended-temperature G3 execution.

ManufacturerYokogawa
Exact modelSAI143-S63
Product typeProSafe-RS 16-Channel 4–20 mA Analog Input Module
01

Product Overview

SAI143-S63 is a Yokogawa ProSafe-RS analog input module for sixteen 4–20 mA field signals with module isolation. The S suffix is the standard non-HART type.

The 6 code selects the signal cable interface adapter with no explosion protection, and the final 3 selects ISA Standard G3 with a -20 to 70 °C operating option. SAI143-S63 therefore uses the specified KS1 cable route rather than a pressure-clamp terminal or MIL cable.

02

Performance

01

Updates all current-input data on a 40 ms cycle.

02

Supports individual 2-wire or 4-wire channel selection through setting pins.

03

Provides module-isolated input with field transmitter power and a 25 mA output-current limit.

04

Can be configured in a dual-redundant arrangement under the documented ProSafe-RS design.

03

Technical Details

Manufacturer Yokogawa Electric Corporation
Exact Model SAI143-S63
Platform ProSafe-RS safety system
Product Type Analog current input module
Channels 16, module isolation
Rated Input 4 to 20 mA
Permissible Input 0 to 25 mA
Standard / HART Code S: standard type without HART communication
Connection Code 6: signal cable interface adapter, no explosion protection
Environmental Code 3: ISA Standard G3 and -20 to 70 °C
Connection Cable KS1-□□*B or KS1-□□*B/SAI143
Pressure Clamp / MIL Not selectable for S63
Rated Accuracy ±16 µA over 1 to 23 mA
Data Update 40 ms
Temperature Drift ±16 µA per 10 °C
Transmitter Supply 16.15 V minimum at 20 mA; 26.4 V maximum at 0 mA
Channel Mode Individual 2-wire or 4-wire selection
Withstand Voltage with Dedicated Cable 500 VAC between input signal and system for one minute
Maximum Current 320 mA at 5 V and 550 mA at 24 V
Redundancy Dual-redundant configuration supported under the documented arrangement
04

System Integration

  • Confirm the installed label is S63, not H63; H identifies the HART communication version.
  • Use the Yokogawa-specific KS1 cable and verify any /SAI143 wrong-insertion-prevention option at both ends.
  • Export the safety application, channel mode, range, alarm limits, bypasses and diagnostic settings before work.
  • Review high-temperature channel-use restrictions when cabinet ambient can exceed 60 °C.
  • Proof-test every channel with controlled current injection and verify safety logic, alarms, bypass removal and redundant behavior.
05

Applications

  • ProSafe-RS 4–20 mA inputs from safety transmitters and fire-and-gas devices.
  • ISA Standard G3 installations requiring the S63 environmental execution.
  • Dual-redundant safety input architecture with the documented matching module and cable arrangement.
06

FAQ

Does SAI143-S63 support HART communication?

No. The S code identifies the standard version; SAI143-H63 is the separate HART-capable execution.

Why can a generic terminal cable not replace the SAI143-S63 KS1 cable?

The S63 code is built for the signal cable interface adapter and Yokogawa-specific KS1 route, including optional wrong-insertion prevention.

What should be reviewed when SAI143-S63 operates above 60 °C ambient?

The manufacturer applies channel-use restrictions for SAI143-S□3 above 60 °C, so cabinet temperature and permitted active-channel count must be checked.

How should redundant SAI143-S63 channels be proof-tested?

Inject controlled current while verifying both module paths, diagnostics, voting behavior, alarms and safe restoration of bypasses.

What evidence should accompany an SAI143-S63 replacement enquiry?

Provide both module labels, KS1 cable codes, adapter and terminal-board identities, channel map, ambient requirement and ProSafe-RS project version.

IndustryParts technical review team

About IndustryParts

https://www.industryparts.com/

Safety input wiring is controlled

IndustryParts matches SAI143-S63 to the KS1 cable, 4–20 mA channel map and ISA Standard G3 installation.

  • S63 suffix retained
  • KS1 cable checked
  • Channel map preserved

Enquiry Information

Send the complete SAI143-S63 label, quantity and destination for an exact enquiry record.

WHATSAPP / PHONE+86 18030175807
Industrial automation replacement support · Exact model and revision control

You May Also Like