INDUSTRIAL COMPONENT DOSSIERSC210G Conductivity Detector
LOW / MEDIUM CONDUCTIVITY · FLOW-THROUGH BODY · ANSI FLANGE

Yokogawa SC210G-A-305 Flow-Through Conductivity Detector

A Yokogawa flow-through conductivity detector for low- and medium-range service with an SCS14 chamber and ANSI flange.

MANUFACTURERYokogawa
EXACT MODELSC210G-A-305
PRODUCT TYPEFlow-Through Conductivity Detector
Detector styleFlow-through
Chamber materialSCS14 stainless steel
FlangeANSI Class 150, 1/2 RF
01
PRODUCT DOSSIER

Product Profile

Yokogawa SC210G-A-305 is an SC210G flow-through conductivity detector intended for low- and medium-range conductivity measurement.

The manufacturer general arrangement drawing identifies an SCS14 chamber, an ANSI Class 150 1/2-inch raised-face flange with serrations and 1/2 NPT inlet and outlet connections.

The exact detector constant and analyzer configuration must be taken from the supplied detector record and connected system documentation rather than inferred from another SC210G suffix.

02
MANUFACTURER DATA

Technical Data

Manufacturer
Yokogawa
Exact model
SC210G-A-305
Product family
SC210G
Detector arrangement
Flow-through
Measurement duty
Low and medium conductivity range
Chamber material
SCS14 stainless steel
Flange
ANSI Class 150, 1/2 RF, serrated
Inlet connection
1/2 NPT
Outlet connection
1/2 NPT
Published overall height
Approximately 409 mm
Installation evidence
Detector and analyzer records required
03
SYSTEM PATH

System Role

INPUT RECORD

Confirm

Verify SC210G-A-305, sample chemistry, pressure, temperature, flow direction, analyzer and calibration record.

CONTROLLED ITEM

SC210G-A-305

Support the assembly, observe the indicated inlet and outlet connections and complete a leak test.

FIELD PROOF

Commission

Enter the approved detector constant, verify temperature response and compare the reading with a traceable sample or standard.

04
MATCH CONTROL

Compatibility

✓

Flow-through measurement path

The chamber arrangement places the conductivity element in a controlled sample stream.

✓

Stainless-steel chamber

SCS14 construction is identified on the Yokogawa drawing.

✓

Defined process interfaces

The drawing identifies the ANSI flange and 1/2 NPT sample connections.

✓

System-level calibration control

Detector constant and analyzer setup remain linked to the supplied detector record.

05
FIELD CONTEXT

Applications

APPLICATION

Sample-line conductivity

Low- and medium-range conductivity monitoring in a compatible process sample loop.

APPLICATION

Flanged installation

Mounting where the specified ANSI Class 150 raised-face connection is provided.

APPLICATION

Detector replacement planning

Matching chamber, process connections, analyzer input and calibration record before exchange.

INDUSTRIAL AUTOMATION SUPPLY SUPPORT

About IndustryParts

https://www.industryparts.com/

Documented handling for SC210G-A-305

IndustryParts keeps the exact model, requested quantity, installed-system evidence and delivery record together so the proposed supply can be checked against the real application before dispatch.

Exact label retained
Application evidence reviewed
Packing record kept traceable
IndustryParts industrial automation support team
06
PROCUREMENT SUPPORT

FAQ

Q01

What installation style does SC210G-A-305 use?

Yokogawa identifies it as a flow-through detector with a stainless-steel chamber and defined sample connections.

Q02

Which flange is shown for SC210G-A-305?

The manufacturer drawing identifies an ANSI Class 150, 1/2-inch raised-face flange with serrations.

Q03

What sample connections apply to SC210G-A-305?

The general arrangement drawing shows 1/2 NPT inlet and outlet connections.

Q04

What should accompany a SC210G-A-305 enquiry?

Provide the complete detector label, analyzer model, detector constant record, flange and piping photographs, process conditions and quantity.

Q05

What proves SC210G-A-305 is ready after installation?

Confirm leak-free flow, correct direction, entered detector constant, stable temperature compensation and agreement with an approved reference.