Yokogawa SC210G-A-305 Flow-Through Conductivity Detector
A Yokogawa flow-through conductivity detector for low- and medium-range service with an SCS14 chamber and ANSI flange.
Product Profile
Yokogawa SC210G-A-305 is an SC210G flow-through conductivity detector intended for low- and medium-range conductivity measurement.
The manufacturer general arrangement drawing identifies an SCS14 chamber, an ANSI Class 150 1/2-inch raised-face flange with serrations and 1/2 NPT inlet and outlet connections.
The exact detector constant and analyzer configuration must be taken from the supplied detector record and connected system documentation rather than inferred from another SC210G suffix.
Technical Data
System Role
Confirm
Verify SC210G-A-305, sample chemistry, pressure, temperature, flow direction, analyzer and calibration record.
SC210G-A-305
Support the assembly, observe the indicated inlet and outlet connections and complete a leak test.
Commission
Enter the approved detector constant, verify temperature response and compare the reading with a traceable sample or standard.
Compatibility
Flow-through measurement path
The chamber arrangement places the conductivity element in a controlled sample stream.
Stainless-steel chamber
SCS14 construction is identified on the Yokogawa drawing.
Defined process interfaces
The drawing identifies the ANSI flange and 1/2 NPT sample connections.
System-level calibration control
Detector constant and analyzer setup remain linked to the supplied detector record.
Applications
Sample-line conductivity
Low- and medium-range conductivity monitoring in a compatible process sample loop.
Flanged installation
Mounting where the specified ANSI Class 150 raised-face connection is provided.
Detector replacement planning
Matching chamber, process connections, analyzer input and calibration record before exchange.
About IndustryParts
https://www.industryparts.com/Documented handling for SC210G-A-305
IndustryParts keeps the exact model, requested quantity, installed-system evidence and delivery record together so the proposed supply can be checked against the real application before dispatch.
FAQ
What installation style does SC210G-A-305 use?
Yokogawa identifies it as a flow-through detector with a stainless-steel chamber and defined sample connections.
Which flange is shown for SC210G-A-305?
The manufacturer drawing identifies an ANSI Class 150, 1/2-inch raised-face flange with serrations.
What sample connections apply to SC210G-A-305?
The general arrangement drawing shows 1/2 NPT inlet and outlet connections.
What should accompany a SC210G-A-305 enquiry?
Provide the complete detector label, analyzer model, detector constant record, flange and piping photographs, process conditions and quantity.
What proves SC210G-A-305 is ready after installation?
Confirm leak-free flow, correct direction, entered detector constant, stable temperature compensation and agreement with an approved reference.