Home>DCS>Yokogawa SC25V-ALP25-225 Combined pH Sensor

Hot Categories

Yokogawa SC25V-ALP25-225 Combined pH Sensor

Yokogawa SC25V-ALP25-225 Combined pH Sensor

Item NO.: 3794802

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameYokogawa SC25V-ALP25-225 Combined pH Sensor
  • Item NO.3794802
  • Weight0.2800 kg = 0.6173 lb = 9.8767 oz
  • CategoryDCS
  • BrandYOKOGAWA
  • Creation Time2026-10-15
LIQUID ANALYSIS / PEEK BODY / 225 MM

Yokogawa SC25V-ALP25-225 Combined pH Sensor

A 225 mm Variopin combined pH sensor with PEEK body, Ag/AgCl reference, titanium liquid earth and Pt1000 temperature element.

ManufacturerYokogawa
Exact modelSC25V-ALP25-225
Product type12 mm Combined pH Sensor
01

Product Profile

SC25V-ALP25-225 integrates the pH glass electrode, reference, liquid earth and temperature element in a 12 mm sensor body for Yokogawa liquid-analysis systems.

The ALP25 construction is the high-temperature, chemical-resistant analog version with intrinsically safe approvals. The 225 suffix identifies the 225 mm insertion length.

Its Variopin connector supports detachable cabling while the PG13.5 process connection fits compatible retractable, flow-through and immersion holders.

02

Technical Data

Manufacturer Yokogawa
Exact model SC25V-ALP25-225
Sensor type Combined pH, reference, liquid earth and temperature
Body diameter 12 mm
Length 225 mm
Connector Variopin
Process connection PG13.5
pH range 0 to 14
Process temperature 15 to 130 °C
Process pressure 0 to 10 bar / 0 to 142 psig
Minimum conductivity Greater than 10 µS/cm
Reference system Ag/AgCl
Temperature element Pt1000 to IEC 751
Liquid earth Titanium
Water protection IP67
Sterilization Up to 135 °C
03

System Role

01

Measures process pH while providing reference, temperature compensation and liquid-earth functions in one sensor.

02

Supports high-temperature hygienic and chemical-process duties within the documented material limits.

03

Uses the Pt1000 element for analyzer compensation and temperature indication.

04

Connects through a Variopin cable to the selected Yokogawa analyzer.

About IndustryParts

https://www.industryparts.com/

Sensor length and process chemistry stay visible

IndustryParts records SC25V-ALP25-225 with its 225 mm geometry, analyzer path and wetted-material requirements before quotation.

  • Insertion length retained
  • Wetted materials reviewed
  • Analyzer path confirmed
IndustryParts product inspection
04

Compatibility

  • Confirm the analyzer accepts a Variopin analog pH sensor with Pt1000 temperature element.
  • Select a compatible PG13.5 holder for the 225 mm sensor length.
  • Check PEEK, AR glass, PTFE, titanium and elastomer compatibility with the process and cleaning regime.
  • Review intrinsic-safety documentation when the installation is in a classified area.
05

Applications

  • High-temperature pH measurement in compatible process and cleaning cycles.
  • Hygienic or chemical applications requiring a 225 mm PG13.5 sensor.
  • Installations benefiting from combined pH, reference, temperature and liquid-earth functions.
06

FAQ

Q01

What installation data is needed for SC25V-ALP25-225?

Provide analyzer, holder, cable, insertion depth, process chemistry, temperature, pressure, cleaning or sterilization cycle and hazardous-area requirement.

Q02

Can SC25V-ALP25-225 replace a 120 mm version?

Not without checking holder geometry and insertion depth. The 225 mm length is a mechanical selection field and must match the assembly.

Q03

What should be reviewed before using SC25V-ALP25-225 in steam sterilization?

Verify the complete holder, cable and process seal arrangement as well as the documented sensor limit of up to 135 °C.

Q04

How is a stored SC25V-ALP25-225 prepared for service?

Follow Yokogawa storage and conditioning guidance, inspect the glass and junction, connect the correct Variopin cable, then perform calibration and stabilization checks.

Q05

What acceptance checks follow SC25V-ALP25-225 installation?

Confirm temperature response, zero and slope calibration, stable reference behavior, liquid-earth integrity, leak-free mounting and agreement with the approved process check.