Home>DCS>Yokogawa UT55A-001-11-00 Digital Indicating Controller

Hot Categories

Yokogawa UT55A-001-11-00 Digital Indicating Controller

Yokogawa UT55A-001-11-00 Digital Indicating Controller

Item NO.: 3790093

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameYokogawa UT55A-001-11-00 Digital Indicating Controller
  • Item NO.3790093
  • Weight0.5000 kg = 1.1023 lb = 17.6370 oz
  • CategoryDCS
  • BrandYOKOGAWA
  • Creation Time2026-10-12
UTADVANCED | 1/4 DIN | RS-485 COMMUNICATION

Yokogawa UT55A-001-11-00 Digital Indicating Controller

A standard-control UT55A execution with universal process input, ladder sequence functions and a dedicated RS-485 network interface.

BrandYokogawa
ModelUT55A-001-11-00
Product TypeUTAdvanced Digital Indicating Controller with RS-485
01

Overview

UT55A-001-11-00 is a Yokogawa UTAdvanced 1/4 DIN digital indicating controller. The 001 function code identifies standard basic control, no added Type 2 I/O package and the Type 3 RS-485 communication selection.

Its universal process input, color LCD, control functions and embedded ladder sequence capability support panel-based temperature and process loops. The complete UT55A-001-11-00 suffix must remain visible because closely related UT55A codes change I/O and network hardware.

02

Specs

Manufacturer Yokogawa Electric Corporation
Model UT55A-001-11-00
Series UTAdvanced
Product Type Digital indicating controller
Panel Size 1/4 DIN; 96 × 96 mm front
Basic Control Code -0 standard type
Type 2 Function Code 0; no additional Type 2 I/O package
Type 3 Network Code 1; RS-485 communication
RS-485 Interface EIA RS-485, two-wire or four-wire half duplex
RS-485 Baud Rates 600 to 38,400 bps for the Type 3 interface
Maximum RS-485 Distance 1,200 m under the specified wiring conditions
Process Input Universal thermocouple, RTD, mV, V or mA input
Measurement Accuracy ±0.1% of full scale for the stated standard conditions
Control Cycle 50, 100 or 200 ms
Display Two five-digit, 14-segment color LCD displays with bar graph
Standard Digital I/O 3 digital inputs and 3 digital outputs
Power Supply 100 to 240 VAC, +10% / -15%
Maximum Power Consumption 18 VA
Front Protection IP66; NEMA 4 water-test basis
03

Features

01

Color-changing process-value display and readable alphanumeric guidance.

02

Universal input supports multiple temperature and process signal families.

03

RS-485 connection supports controller integration without adding an external gateway.

04

Ladder sequence function is included for interlocks and local logic.

04

Applications

  • Temperature and process loops requiring a 96 × 96 mm panel controller.
  • RS-485 supervisory links carrying process value, setpoint, output and alarm data.
  • Skids and legacy panels where local display, PID control and discrete interlocks share one controller.
05

Lifecycle

  • Export the parameter map and record input range, control mode, PID values, alarms and ladder sequence before removal.
  • Capture RS-485 address, baud rate, parity, protocol, two- or four-wire topology and termination.
  • Confirm the complete UT55A-001-11-00 suffix and power supply before moving field conductors.
  • After replacement, test sensor scaling, control direction, outputs, alarms, communications and safety interlocks under an approved startup plan.
06

FAQ

Why can a UT55A-001-11-00 communicate intermittently after replacement?

A mismatched address, baud rate, parity, protocol, wire mode or termination can pass occasional traffic yet remain unstable; compare every serial setting with the saved network record.

What should be photographed before ordering UT55A-001-11-00?

Capture the complete side label, terminal wiring, panel cutout, supply terminals and the RS-485 conductors so the suffix and installation are independently verifiable.

Can another UT55A code replace UT55A-001-11-00?

Only after its basic-control, added-I/O and network codes are compared. Similar fronts can hide different terminal and communication hardware.

Which backup is most useful before changing UT55A-001-11-00?

Retain the full parameter map, ladder sequence, calibration-related settings, display assignments and serial communication setup.

What proves a successful UT55A-001-11-00 commissioning?

Record stable measured value, correct output direction, alarm and interlock tests, setpoint response and error-free RS-485 polling.

You May Also Like