Detail

  • Product NameYokogawa ZR802G Zirconia Oxygen / Humidity Analyzer Converter
  • Item NO.3794589
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandYOKOGAWA
  • Creation Time2026-10-15
PROCESS GAS ANALYSIS | TOUCHSCREEN HMI | ZR22G DETECTOR SYSTEM

Yokogawa ZR802G Zirconia Oxygen / Humidity Analyzer Converter

A separate-type zirconia oxygen and high-temperature humidity analyzer converter with touchscreen operation and digital communications.

ManufacturerYokogawa
Exact modelZR802G
Product typeZirconia Oxygen / Humidity Analyzer Converter
01

Product Overview

ZR802G is the Yokogawa converter used with the ZR22G detector in a separate-type zirconia oxygen or high-temperature humidity analyzer. It displays oxygen concentration, cell temperature and cell electromotive force.

The converter includes a touchscreen human-machine interface and supports the system used for direct measurement in flues, furnaces and dryers without a sampling device. The complete suffix and option code must be taken from the installed nameplate.

02

Performance

01

Provides continuous oxygen-concentration or high-temperature humidity measurement with a compatible detector.

02

Displays oxygen concentration, zirconia cell temperature and cell electromotive force.

03

Uses a touchscreen HMI for setup, indication, diagnostics and maintenance access.

04

Supports documented HART and MODBUS communication options according to the ordered execution.

03

Technical Details

Manufacturer Yokogawa Electric Corporation
Exact model ZR802G
Product type Zirconia oxygen / humidity analyzer converter
System arrangement Separate type with compatible ZR22G detector
Measured applications Oxygen concentration or high-temperature humidity
Displayed variables Oxygen concentration, cell temperature and cell EMF
Operator interface Digital display with touchscreen HMI
Communication resources Documented HART and MODBUS options
Typical process use Boilers, industrial furnaces, combustion equipment and dryers
Selection basis Complete suffix and option code from the nameplate
04

System Integration

  • Record the complete ZR802G suffix, options, power source, detector code, probe length and cable arrangement.
  • Export or document analyzer range, calibration settings, alarms, outputs and digital communication parameters.
  • Confirm that the connected ZR22G detector, calibration-gas system and reference-air arrangement match the converter configuration.
  • After installation, complete warm-up, diagnostics, calibration and loop checks according to the Yokogawa manual.
05

Applications

  • Combustion-oxygen monitoring for industrial boilers, furnaces and other combustion equipment.
  • Low-oxygen combustion control intended to improve efficiency and operating cost.
  • High-temperature humidity measurement in dryers that use electric heaters or hot gas.
06

FAQ

Q01

What nameplate details are needed for a ZR802G enquiry?

Provide the complete suffix and option string, supply voltage, communication option, detector code and clear photographs of both converter and probe labels.

Q02

Can ZR802G be selected without identifying the connected detector?

No. Confirm the ZR22G detector execution, probe length, cable, process connection and measurement application.

Q03

What settings should be backed up before replacing ZR802G?

Record range, alarms, output scaling, calibration data, display settings and any HART or MODBUS parameters.

Q04

What process evidence helps diagnose unstable ZR802G readings?

Review probe condition, process leaks, reference air, calibration gas, cell temperature, dust loading and wiring before replacing the converter.

Q05

What commissioning record should follow ZR802G replacement?

Retain warm-up status, diagnostic results, calibration values, analog-loop checks, communication checks and comparison with expected process oxygen.

IndustryParts office verification

About IndustryParts

https://www.industryparts.com/

Analyzer enquiries include the probe and process context

IndustryParts prepares ZR802G requests with the converter options, connected detector, calibration arrangement and communication record aligned.

  • Full suffix requested
  • Detector pairing confirmed
  • Calibration record retained

Enquiry Information

Send the complete ZR802G label, quantity and destination for an exact enquiry record.

WHATSAPP / PHONE+86 18030175807