Bently Nevada 200151-40-03-02 Armored Accelerometer Interface Cable
A 4.0-metre blue armored interface cable with molded connectors on both ends and nylon coupling nuts.
Product Overview
200151-40-03-02 is the 200151 interface cable used between compatible 20015x accelerometers and their approved monitoring interfaces.
The 40 code selects 4.0 metres, 03 selects the blue armored cable and 02 selects nylon coupling nuts. Connectors are molded to the cable and provide an IP67 seal when correctly mated.
The cable uses four 22 AWG conductors with braided shielding and drain wire. Routing must respect the published bend and temperature limits.
Performance
Connect both ends without field splicing
The 200151 design carries molded connectors on the accelerometer and interface ends.
Protect signal conductors
Armor and braided shielding support mechanically protected, noise-conscious routing.
Seal the mated connection
Correctly coupled connectors provide the documented environmental seal.
Technical Details
| Manufacturer | Bently Nevada | Exact model | 200151-40-03-02 |
|---|---|---|---|
| Cable family | 200151 | Cable length | 4.0 m |
| Armor option | Blue cable with armor | Coupling nuts | Nylon |
| Conductors | 4 × 22 AWG | Shield | Braided with drain wire, 85% minimum coverage |
| Connector arrangement | Molded connectors on both ends | Mated sealing | IP67 |
| Minimum bend radius | 63.5 mm (2.5 in) | Operating temperature | -20°C to +100°C |
About IndustryParts
https://www.industryparts.com/Cable endpoints and routing are reviewed together
IndustryParts keeps the exact 4-metre cable identity, both connected devices and requested quantity in one quotation record.
- •Exact submitted model retained
- •Installed-system evidence reviewed
- •Requested quantity linked to the enquiry
System Integration
Identify the endpoints
Record the accelerometer and receiving interface before disconnecting the original cable.
Plan the 4 m route
Keep the cable free from tension, hot surfaces, tight bends and unsupported armor.
Inspect both connectors
Check pins, seals and nylon coupling nuts before mating.
Test the channel
Verify continuity, shield condition and the live accelerometer signal after installation.
Applications
Accelerometer signal connection
Linking a compatible 20015x sensor to ProTIM, flexiTIM or other supported hardware.
Protected machinery routing
Using the armored construction where the approved route needs added mechanical protection.
Serviceable sealed connection
Maintaining molded, mated connectors in humid industrial environments.
FAQ
Which endpoints should be listed for a 200151-40-03-02 quotation?
Provide the accelerometer model, interface hardware, connector photographs and the measured route.
Can 200151-40-03-02 be flexed below -20°C?
The manufacturer warns that flexing or bending the cable below -20°C may damage it.
Why must the bend radius be checked for 200151-40-03-02?
The armored cable requires at least the published 63.5 mm radius to avoid mechanical damage.
Can a 200152 cable replace 200151-40-03-02?
No direct assumption should be made; 200152 has a connector only at the accelerometer end and a different termination plan.
What closes a 200151-40-03-02 installation record?
Correct endpoint matching, sealed connectors, compliant routing and a stable accelerometer channel complete acceptance.
Request a model-specific quotation
Send the complete 200151-40-03-02 label, requested quantity, delivery destination and installed-system context.