Home>TSI>Bently Nevada 330901-10-60-70-02-05 3300 NSv Proximity Probe

Hot Categories

Bently Nevada 330901-10-60-70-02-05 3300 NSv Proximity Probe

Bently Nevada 330901-10-60-70-02-05 3300 NSv Proximity Probe

Item NO.: 3800851

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameBently Nevada 330901-10-60-70-02-05 3300 NSv Proximity Probe
  • Item NO.3800851
  • Weight0.0400 kg = 0.0882 lb = 1.4110 oz
  • CategoryTSI
  • BrandBently Nevada
  • Creation Time2026-10-19
Seven-meter 1/4-28 UNF NSv probe for restricted-clearance measurements

Bently Nevada 330901-10-60-70-02-05 3300 NSv Proximity Probe

An unarmored 3300 NSv probe with a long case, 7 m cable and ClickLoc termination for constrained installations.

01

Product Profile

Bently Nevada 330901-10-60-70-02-05 is a 3300 NSv proximity probe with 1/4-28 UNF thread and no armor. Its ordering code defines 1.0 in unthreaded length, 6.0 in overall case length, 7.0 m total probe length, a ClickLoc connector with standard cable and Multiple Approvals.

The NSv system is intended for machines where counterbore, side-view or rear-view restrictions limit standard 5 mm or 8 mm systems. It also supports small-target radial vibration, axial position, tachometer, zero-speed and phase-reference applications when the full NSv chain is correctly selected.

02

Technical Data

Manufacturer
Bently Nevada
Exact model
330901-10-60-70-02-05
Probe family
3300 NSv
Thread
1/4-28 UNF
Armor
Without armor
Unthreaded length
1.0 in
Overall case length
6.0 in
Total probe length
7.0 m
Connector
Miniature coaxial ClickLoc, standard cable
Approval option
Multiple Approvals
System linear range
1.5 mm (60 mil)
Recommended gap
1.0 mm (40 mil)
Average scale factor
7.87 V/mm (200 mV/mil)
Typical frequency response
0 to 10 kHz, +0/-3 dB
03

System Role

01

Narrow-side-view geometry supports locations where standard proximity probes have insufficient clearance.

02

The NSv system provides a 1.5 mm linear range and the common 200 mV/mil scale-factor class.

03

The 7 m probe is selected as a complete ordering execution rather than created by field extension of a shorter probe.

04

Small-target and cross-talk constraints must be reviewed when probes are closely spaced.

04

Compatibility & Service

  • Record the complete probe, extension cable and NSv Proximitor sensor codes.
  • Maintain the documented minimum probe-tip separation where adjacent sensors could interact.
  • Preserve the long probe case from bending and support the 7 m cable without tensile load.
  • After installation, confirm gap, scale response, channel polarity and frequency behavior.
05

Applications

  • Centrifugal air, refrigeration and process-gas compressor monitoring.
  • Radial vibration and position measurement on small shafts.
  • Axial position measurement on restricted flat targets.
  • Tachometer, zero-speed and phase-reference sensing with the compatible NSv chain.
06

FAQ

Q01Why is 330901-10-60-70-02-05 not interchangeable with a standard 3300 XL 8 mm probe?

NSv has different small-target, side-view and linear-range behavior and must be used with the compatible NSv extension cable and Proximitor sensor.

Q02What dimensional evidence is needed for this long-case 330901 probe?

Provide insertion depth, bracket thickness, counterbore diameter, target clearance and the available path for the 6.0 in case and 7 m cable.

Q03Can a shorter cable be substituted for the 70 option?

Only by redesigning and documenting the complete NSv system-length combination; the submitted probe is specifically configured as a 7 m execution.

Q04What can cause cross-talk in a 330901-10-60-70-02-05 installation?

Closely spaced probe tips on small shafts can allow their electromagnetic fields to interact, so target size and tip separation must be checked.

Q05What should be included in a replacement acceptance record?

Keep the exact probe and Proximitor identities, final gap, target geometry, cable routing, static output, dynamic response and channel alarm test.