Bently Nevada 330905-00-25-05-02-IN NSv Proximity Probe
An M10×1 NSv probe with a 250 mm case, 0.5 m standard cable and nameplate-specific IN suffix.
Product Identification
330905-00-25-05-02-IN identifies a metric 3300 XL NSv proximity probe based on the 330905 M10×1, non-armored construction. The mechanical order fields specify zero unthreaded length, a 250 mm case and 0.5 m total probe length.
The IN suffix is retained exactly from the submitted identity but should be confirmed against the installed label and project approval documentation before supply.
Engineering Data
| Manufacturer | Bently Nevada, a Baker Hughes business |
|---|---|
| Complete Model | 330905-00-25-05-02-IN |
| Probe Family | 3300 XL NSv |
| Case Thread | M10×1 |
| Armor | Without armor |
| Unthreaded Length | 0 mm |
| Overall Case Length | 250 mm |
| Total Probe Length | 0.5 m |
| Connector / Cable | ClickLoc, standard cable, no protector |
| Final Suffix | IN — verify against nameplate and project records |
Functions
- Provides non-contact proximity measurement where restricted side-view clearance favors the NSv system.
- Uses an M10×1 long-case construction for metric mounting arrangements.
- Connects to the selected NSv extension cable and Proximitor Sensor as a calibrated system.
- Supports rotating-machine vibration and position measurements within the system application limits.
Applications
- Metric long-reach compressor measurements
- Axial-position and radial-vibration loops
- Constrained NSv probe installations
Lifecycle
- Retain photographs of the complete label because the final suffix needs project-level verification.
- Keep the exact case geometry with the machine probe-location drawing.
- Manage every probe-system component under the same loop record.
FAQ
Why was 330905-0-25-05-02-IN normalized to 330905-00-25-05-02-IN?
The metric ordering structure uses a two-character unthreaded-length field, so 00 is the complete zero-length code.
How should the IN suffix on 330905-00-25-05-02-IN be handled?
Confirm it from the original nameplate and controlled project documents before ordering; do not substitute another approval suffix by assumption.
What mechanical check is critical for 330905-00-25-05-02-IN?
The 250 mm case requires confirmation of insertion depth, straightness, thread engagement and rear clearance.
Can 330905-00-25-05-02-IN be mixed with standard 8 mm probe-system parts?
No. Use the corresponding 3300 XL NSv cable and Proximitor Sensor with a matched total system length.
What acceptance test follows a 330905-00-25-05-02-IN replacement?
Verify gap voltage, linear response, dynamic signal, channel scaling and configured alarms under the site procedure.