Home>TSI>Bently Nevada 3500/46M 176449-06 Hydro Monitor

Hot Categories

Bently Nevada 3500/46M 176449-06 Hydro Monitor

Bently Nevada 3500/46M 176449-06 Hydro Monitor

Item NO.: 3770622

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameBently Nevada 3500/46M 176449-06 Hydro Monitor
  • Item NO.3770622
  • Weight0.9100 kg = 2.0062 lb = 32.0993 oz
  • CategoryTSI
  • BrandBently Nevada
  • Creation Time2026-09-16
3500 SERIES | HYDRO MONITOR SPARE

Bently Nevada 3500/46M 176449-06 Hydro Monitor

The 176449-06 Hydro Monitor for multi-parameter protection and multimode operation in a 3500 rack.

BrandBently Nevada
Model3500/46M 176449-06
Product TypeHydro Monitor
01

Key Information

3500/46M 176449-06 is the Bently Nevada Hydro Monitor spare identified in the current 3500/46M documentation. It is not a 3500/50M tachometer part.

The monitor conditions selected hydro-machine transducer signals, compares measurements with programmed alarms and supports operating-mode changes where a plant requires different protection settings.

02

Functions

  • Processes compatible proximity, air-gap, velocity, acceleration and dynamic-pressure signal families.
  • Supports hydro measurement functions such as radial vibration, thrust position and stator-related monitoring when correctly configured.
  • Provides multiple alarm or setpoint arrangements for changing machine operating modes.
  • Offers front buffered outputs for service measurements and recorder outputs for plant interfaces.
03

Specifications

Manufacturer Bently Nevada, a Baker Hughes business
Complete Identification 3500/46M 176449-06
Product Family 3500 Machinery Protection System
Product Role Hydro Monitor
Input Capacity One to four sensor signals
Typical Power Consumption 7.7 W
Recorder Outputs Four 4–20 mA outputs
Buffered Output Impedance 550 Ω
Rack Position One full-height front slot with matching rear I/O slot
04

Installation

  • Identify the fitted rear I/O module and every sensor loop before removing the existing monitor.
  • Restore channel functions, mode logic, scaling, alarm levels and plant communication settings from the controlled backup.
  • Keep external termination blocks and cables matched to the external-I/O option; do not combine them with an internal-termination module.
  • Functionally test each operating mode and protective output after commissioning.
05

Lifecycle

  • Maintain the monitor, rear I/O and transducer records as one protection-loop package.
  • Verify rack firmware and configuration-software compatibility before installing a replacement.
  • Retain proof-test results and alarm-change authorization with the machine safety documentation.
07

FAQ

Why is the correct identity 3500/46M 176449-06 rather than 3500/50M 176449-06?

Bently Nevada assigns part 176449-06 to the Hydro Monitor; the 3500/50M family uses different tachometer monitor spares.

Which rear I/O should accompany 3500/46M 176449-06?

Select it from the sensor mix, termination method and whether multimode or positive-input channels are required.

How are operating modes changed on 3500/46M 176449-06?

Use the configured rack contact logic or supported software-gateway method defined by the plant design.

What configuration must be preserved for 3500/46M 176449-06?

Save every channel function, sensor scale, mode setpoint group, alarm delay and communication mapping.

Can 3500/46M 176449-06 be commissioned from a single static check?

No. Each sensor path, alarm path and configured operating mode should be validated separately.

What information should accompany a 3500/46M 176449-06 quotation request?

Provide rear-I/O part numbers, sensor models, rack revision, mode logic and the existing configuration backup.