Bently Nevada 84661-55 55 ft Armored Interconnect Cable
A shielded 22 AWG armored cable with a moisture-resistant sensor connector and monitor-end ring lugs.
Overview
84661-55 is a 55 ft Bently Nevada standard armored interconnect cable for compatible velocity-transducer systems. It uses stainless steel armor over a shielded 0.382 mm² (22 AWG) cable.
A moisture-resistant female connector terminates the transducer end, while ring lugs provide the monitor-end connection. The 55 suffix specifies cable length in feet.
Specs
| Manufacturer | Baker Hughes Bently Nevada |
|---|---|
| Exact Model | 84661-55 |
| Product Type | Standard armored interconnect cable |
| Ordered Length | 55 ft (approximately 16.8 m) |
| Conductor Size | 0.382 mm² (22 AWG) |
| Cable Construction | Shielded cable with stainless steel armor |
| Transducer-End Termination | Moisture-resistant female connector |
| Monitor-End Termination | Ring lugs |
| Operating Temperature | -29 to +121 °C (-20 to +250 °F) |
| Family Length Range | 3 to 96 ft (0.91 to 29 m) |
| Documented System Use | Compatible Bently Nevada velocity-transducer installations |
Features
- Stainless steel armor provides mechanical protection for the shielded signal cable.
- The 55 ft ordering length is part of the exact cable identity.
- Moisture-resistant female connector mates at the compatible transducer end.
- Ring-lug monitor termination supports cabinet field wiring.
- The 22 AWG shielded construction supports low-level velocity-sensor signal routing.
Applications
- Interconnection of compatible Bently Nevada low-frequency velocity transducers to monitoring equipment.
- High-temperature Velomitor installations that list the 84661 armored cable family.
- Longer machinery-monitoring cable runs requiring 55 ft of protected routing.
- Industrial locations where flexible stainless steel armor is preferred over an unarmored cable.
- Replacement of an existing cable with the same connector, ring-lug and length arrangement.
Lifecycle
- Preserve the exact 84661-55 part number because the 55 suffix defines the ordered cable length.
- Confirm the mating transducer connector and monitor-end ring-lug wiring before replacement.
- Route the armored cable without crushing, sharp bends or contact with damaging surfaces.
- Maintain shield continuity and follow the monitor wiring plan to control electrical noise.
- Verify cable continuity, polarity and sensor response before returning the channel to service.
FAQ
How long is 84661-55?
84661-55 is ordered as a 55 ft cable, approximately 16.8 m.
Is 84661-55 armored?
Yes. 84661-55 uses stainless steel armor over shielded 0.382 mm² (22 AWG) cable.
Which connectors are fitted to 84661-55?
84661-55 has a moisture-resistant female connector at the transducer end and ring lugs at the monitor end.
What temperature range applies to 84661-55?
84661-55 is specified for -29 to +121 °C (-20 to +250 °F).
Which installations use 84661-55?
84661-55 is listed for compatible Bently Nevada velocity-transducer systems, including low-frequency and high-temperature sensor arrangements.
What should be checked when replacing 84661-55?
Confirm the 55 ft route, mating connector, ring-lug assignments, shield continuity and channel polarity for 84661-55.
Recommended Models
| MPPES-3-1/2-10-010 | 1794-IB32 | BSM80A-150AF |
| MD90785 | TRIO-PS-2G/1AC724DC/5 | 3KL61 301AB0 |
| EST3 SFS1-ELEC | 032-250/1102 G10 | BMXXBP0600 |
| V 50.1 BR3 A40 T12 | TSXCFY21 | A16B-3300-0057 |
| Festo DNC-32-150-PPV-A | CNXRY-16 | AGEV1-09388-A/HM |
| UMG96S 52.13.025 | X87-813 | Micro 2X16 III 10T128P ZAA6K4K9DPGS |
| QD77MS2 | DDNP1501 | EDA61K-HB-0 |
| Siemens 3SB1831-7AH | RK27-24H | QSM3-XW-C |
| LEGRAND 03842 | MAD130D-0200-SL-M6-FP1-05-V1 | V50017-U341-K500 STM-16 |
| 4AM4042-8DN00-0EA0 | DILM72 XTCE072D00F | H2EWXBBL57D |