Product Profile
Ranger Pro 70M403 is the tri-axial WirelessHART version of the Bently Nevada Ranger Pro sensor. It acquires acceleration, velocity, temperature, waveforms, spectra and PeakDemod information for wireless machinery monitoring.
The model is recommended for WirelessHART gateways and uses HART IP when exchanging dynamic data with System 1. The four ordering fields for mounting, radio, battery and approval must still be completed.
Technical Data
| Manufacturer | Bently Nevada, a Baker Hughes business |
|---|---|
| Model | Ranger Pro 70M403 |
| Sensor Type | Tri-axial wireless accelerometer with integral temperature sensor |
| Wireless Protocol | WirelessHART |
| Sensing Element | Piezoelectric ceramic |
| Acceleration Range | ±20 g peak |
| Accuracy at 160 Hz | Z axis ±5%; X/Y axes ±10% |
| Acceleration Bandwidth | Z: 5 Hz–10 kHz; X/Y: 5 Hz–4 kHz |
| Velocity Range | 0–50 mm/s (0–2 in/s), 5–2000 Hz |
| Temperature Sensor | -40 to 120 °C; 0.1 °C resolution; ±1 °C typical, ±3 °C maximum |
| Radio | IEEE 802.15.4, 2.405–2.475 GHz; OQPSK DSSS |
| Wireless Security | 128-bit AES encrypted packets |
| Line-of-Sight Range | 150 m to access point; 100 m sensor to sensor |
| Operating Temperature | -40 to 85 °C |
| Enclosure | IP67; 316 stainless-steel body with glass-reinforced PPS top |
| Battery | Replaceable D-size 3.6 V lithium-thionyl chloride; up to five years |
| System 1 Compatibility | Version 20.2 or higher; confirm release-note guidance |
| Ordering Format | 70M403-AA-BB-CC-DD; mounting, radio, battery and approval fields required |
System Role
- Provides three-axis wireless vibration and integral temperature data through a WirelessHART network.
- Supports overall-value publication by gateway and dynamic data exchange through HART IP.
- Can participate in a mesh network and route data for other Ranger Pro sensors.
- Enables configurable measurement intervals, thresholds and severity states.
Compatibility
- Use a compatible WirelessHART gateway and verify its required firmware.
- Confirm System 1 version, HART IP or GCI licensing and the site network design.
- Select mounting hardware, battery and agency approval for the actual machine point.
- Check radio path, hop depth, sensor orientation and hazardous-area requirements.
Applications
- Wireless monitoring of motors, pumps, fans, blowers and compressors.
- Hard-to-access or cable-prohibitive machinery locations.
- System 1 wireless condition-monitoring expansion.
FAQ
Can Ranger Pro 70M403 be provisioned on an ISA100-only gateway?
No protocol match should be assumed; 70M403 is the WirelessHART model and should use a compatible WirelessHART architecture.
Which gateway information should accompany a Ranger Pro 70M403 request?
Provide gateway model, firmware, sensor count, planned hop depth, HART IP or interface licensing and System 1 version.
Why must the mounting option be chosen carefully for Ranger Pro 70M403?
Tri-axis interpretation and X/Y accuracy depend on correct orientation and appropriate alignment hardware.
Does the Ranger Pro 70M403 base model include a battery and approval selection?
Those are separate ordering fields; specify battery inclusion and the required North American or ATEX/IECEx option.
How should wireless range be validated for Ranger Pro 70M403?
Perform a site survey considering obstacles, antenna type, sensor orientation, mesh routing and the intended gateway location.
What commissioning evidence is needed for Ranger Pro 70M403?
Record device tag, mounting orientation, network health, firmware, measurement configuration, data quality and alarm/severity checks.
Recommended Models
| CH5 00N0M356C1 | LI44/25-1150Q-ZEN/E | ET1212PPH-S-DR |
| U20NRUD300 000 RS485 | Allen Bradley 184861 | 6ES7 222-1BH30-0XB0 |
| EDT230010R | V601MPC | SB-3SBXS-WL |
| X20 PD 0011 Rev.F0 | 63.1 BR2 A40 T12 P+F 281344 | ABB ACS401001632 |
| MG5424 | 4E0021.01-590 | SF47 DRN71M2/BE05/Z |
| 130B1430 | Siemens 6FX1136-8BA01 | ABB SACE EMAX2 E1.2 N 630 1SDA072704R1 |
| TXS1.EF4 | Veris TWXH00 | HS2032PCBCE |
| 21HC | 01-9593-R0P | JBBS-25-E413 |
| 3IF050.6 | 089UDA40XBFWBC100190-SRDN | 3VL4740-2SB36-0AB1 |
| IV3-G120 | 3-K Lumi 18R | ALSPA MD2000 61-400 |