Processes two independent eddy-current differential inputs for shaft eccentricity measurement.
Product Overview
A6220 is an Emerson AMS 6500 Shaft Eccentricity Monitor. The 3U, one-slot module accepts two independent eddy-current measurement paths and is designed for machinery protection applications.
The monitor is used to observe slow-roll shaft eccentricity below 600 rpm and supports compatible PR6422, PR6423, PR6424 and PR6425 sensor systems.
Performance
Covers an input frequency range of 0.017 to 70 Hz, corresponding to 102 to 4200 rpm in the documented configuration.
Provides selectable measurement spans from 0–400 mV peak minimum to 0–8000 mV peak maximum.
Performs continuous checks of hardware, power, temperature and sensor/cable condition.
Technical Details
| Manufacturer | Emerson |
|---|---|
| Monitoring platform | AMS 6500 Machinery Health Monitor |
| Measurement function | Shaft eccentricity below 600 rpm |
| Channel count | Two independent channels |
| Form factor | 3U, one slot |
| Compliance | API 670; hot-swappable module design |
| Compatible sensor families | PR6422, PR6423, PR6424 and PR6425 |
| Input resistance | > 100 kΩ |
| Input voltage range | -1 to +23 V DC |
| Input frequency range | 0.017 to 70 Hz |
| Measurement span range | 0–400 mV peak minimum to 0–8000 mV peak maximum |
| Sensor supply | -26.7 V DC nominal; 20 mA nominal, 35 mA maximum |
| Analog outputs | 0/4–20 mA and 0–10 V |
| Current-output load | < 500 Ω; accuracy ±1% |
| Voltage-output load | > 10 kΩ |
| Operating temperature | 0 to +65 °C |
| Relative humidity | 5 to 95%, non-condensing |
| Maximum power consumption | 6 W |
System Integration
- Confirm rack slot, channel configuration, sensor family, converter calibration and voting logic before replacing A6220.
- Back up the AMS 6500 configuration and record alarm, danger, bypass and remote limit-multiply settings.
- Verify buffered and analog output destinations as well as sensor supply and cable condition.
- Test slow-roll measurement and the full protection path before restoring trip service.
Applications
- Slow-roll shaft eccentricity monitoring on critical rotating machinery.
- AMS 6500 protection systems requiring a two-channel API 670 monitor.
- Retrofit or replacement work using compatible Emerson eddy-current sensor systems.
FAQ
What sensor information is required before ordering A6220?
Provide both sensor and converter models, sensitivity, cable length, channel scale and the existing AMS 6500 configuration.
Can A6220 be hot-swapped without process planning?
The module design is hot-swappable, but protection bypass, voting impact, rack procedure and site authorization must still be planned before removal.
Why does A6220 need a slow-roll commissioning check?
Eccentricity is evaluated at low speed, so slow-roll behavior, runout and phase reference must be verified under the machine-specific protection plan.
What should be backed up before replacing A6220?
Save the complete rack configuration, channel scales, filters, alarm and danger thresholds, relay logic, bypass state and output assignments.
How should an A6220 spare be accepted?
Verify exact identity, connector and card-edge condition, calibration/test evidence, ESD packaging and compatibility with the installed rack release.
About IndustryParts
https://www.industryparts.com/Protection settings remain part of the supply record
IndustryParts handles A6220 with the rack, sensor and channel-configuration evidence needed for a controlled machinery-protection replacement.
- Rack context recorded
- Sensor path checked
- Protection settings preserved
Recommended Models
| R44-277-RENA | BRMTP4-1 | T91A61 PN:5017-611 |
| CAT5e/6/7 | ADS 50/5 | SV9342.320 |
| Siemens 3UG4614-1BR20 | Inspiroy H950P | 8JSA33.R0045D000-0 |
| 0407 A 50.0 EG GG 00085404 | DSG-B10148 | USST4 3070338 |
| LD4LC130F 010510 | TM218LDA24DRN | MK13-UPF-EX0/K06 |
| ifm GM701S | GH118-GYDXI | 3BSE000469R1 |
| 94.74SMA | C200HW-DRM21-V1 DRM21-V1 | NOKIA 3HE00868CBAA01 |
| DO135 | DLC-MASTER/DSP | EL7342 |
| KWE30.00.170.10 | XD3 XD1033 | IC693PWR330E |
| 1LA9183-4WA60-Z | ZDR 6 DP2-45/75YM R900483786 | 5IK40GN-C |