PR6426 MEASUREMENT CHAIN · 20.0 MM EXTENDED RANGE · PANEL MOUNT
Emerson CON021/916-200 Eddy Current Signal Converter
A factory-calibrated panel converter execution for a PR6426 eddy-current sensor chain with a 20.0 mm extended measuring range.
Overview
CON021/916-200 is the panel-mount signal converter execution listed by Emerson for use with the PR6426 large-range eddy-current sensor. The /916-200 code identifies a 20.0 mm extended measuring range and a maximum linearity error of 2.5 percent.
The converter is one element of a factory-calibrated measurement chain. Probe, extension cable and converter identity therefore remain linked when the system is quoted, replaced or recalibrated.
Specifications
Features
Large-displacement conversion
Processes the PR6426 signal over the published 20.0 mm extended range.
Calibrated system relationship
Retains the probe, cable and converter as a matched measurement chain rather than three generic parts.
Panel service format
Places the signal-conversion electronics in a panel-mount housing for controlled cabinet integration.
Protection-system use
Supports machinery-monitoring chains where repeatable gap and displacement signals feed the approved monitor.
About IndustryParts
https://www.industryparts.com/Exact identity before quotation
IndustryParts prepares CON021/916-200 enquiries around the complete manufacturer label, requested quantity and destination. For controlled replacements, include the host-system record, field photographs and configuration evidence that apply to this exact execution.
Applications
Large shaft movement
Monitoring displacement or position where the PR6426 range is required.
Machinery protection loops
Supplying a conditioned eddy-current signal to the documented protection or monitoring channel.
Controlled spare replacement
Restoring a converter only after the paired sensor and cable identities have been captured.
Lifecycle
Record the chain
Photograph the PR6426 probe, extension cable and CON021/916-200 labels and save the monitor-channel setup.
Preserve the match
Fit the exact converter execution without substituting a different /916 range code.
Prove the loop
Check gap, full travel, polarity, alarm response and channel scaling under the approved procedure.
FAQ
Can CON021/916-200 be replaced by another CON021/916 execution?
Not by code similarity alone. The range and calibration relationship must match the PR6426 measurement chain and the monitor-channel setup.
What should accompany a CON021/916-200 quotation?
Provide clear labels for the converter, PR6426 probe and extension cable, plus cable length, installed gap, monitor channel and requested quantity.
Does CON021/916-200 operate as a stand-alone displacement instrument?
No. Its published role is within a calibrated eddy-current chain that includes the compatible probe and cable.
What field evidence helps diagnose a suspected CON021/916-200 problem?
Record supply condition, static gap voltage, target movement, connector condition and the response observed at the receiving monitor.
What closes a CON021/916-200 replacement record?
A documented zero or gap check, travel check, channel scaling review and alarm proof test provide the acceptance evidence.
Send the complete CON021/916-200 label, requested quantity and destination.