Carries the VersaMax expansion-bus signals between the main rack and one IC200ERM002 rack.
Product Overview
IC200CBL600C is the C revision of the VersaMax IC200CBL600 single-ended inter-rack expansion cable.
The cable connects a VersaMax CPU or NIU serial expansion port to the receiving port of one non-isolated IC200ERM002 expansion rack when no Expansion Transmitter is used.
The documented maximum cable length for this single-ended arrangement is one metre. The cable is ordered as a manufactured assembly rather than fabricated in the field.
Performance
Provides the specified shielded single-ended connector arrangement.
Maintains the one-metre physical limit for the documented topology.
Preserves the C revision for spare and drawing traceability.
Technical Details
| Manufacturer | Emerson / legacy GE Fanuc |
|---|---|
| Exact model and revision | IC200CBL600C |
| Platform | VersaMax modular I/O |
| Cable function | Single-ended inter-rack expansion connection |
| Cable length | 1 m |
| Construction | Shielded manufactured cable assembly |
| Main-rack connection | VersaMax CPU or NIU serial expansion port |
| Expansion connection | IC200ERM002 receiving port |
| Supported topology | One non-isolated expansion rack without Expansion Transmitter |
| Terminator plug | Not required for the documented single-ended arrangement |
| Field fabrication | Not permitted for this cable type |
| Revision control | C suffix retained |
System Integration
- Use only for the single-ended VersaMax expansion arrangement documented for IC200CBL600.
- Confirm the receiving module is IC200ERM002 and no Expansion Transmitter is in this topology.
- Do not treat two-ended IC200CBL601/602/615 cables as equivalent.
- Protect the connector orientation, shield path and one-metre routing limit.
Applications
- Two-rack local VersaMax systems with one non-isolated expansion rack.
- Replacement of a damaged or contaminated single-ended expansion cable.
- Controlled rebuilds where the original cable code and connector path are documented.
- Service spares requiring the exact C revision on the record.
About IndustryParts
https://www.industryparts.com/A cable is selected by topology, not length alone
IndustryParts keeps IC200CBL600C linked to its single-ended VersaMax arrangement, connector path and C revision.
- Single-ended topology confirmed
- One-metre route checked
- C revision retained
FAQ
Can IC200CBL600C be fabricated from generic cable?
No. The VersaMax manual says the single-ended IC200CBL600 assembly must be ordered; it is not a field-fabricated cable.
What must be photographed before ordering IC200CBL600C?
Capture the full cable label, both connector faces, CPU or NIU model, IC200ERM002 label, rack spacing, shield condition and route.
Can IC200CBL601 replace IC200CBL600C?
Do not assume it can. IC200CBL600 is single-ended for a specific one-rack topology; IC200CBL601 is a different two-connector expansion cable.
What installation faults can resemble a failed IC200CBL600C?
Check rack power, connector seating, bent pins, cable damage, shield bonding, the ERM receiving port and an unsupported topology before condemning the cable.
What proves IC200CBL600C is ready after exchange?
Confirm exact routing and seating, healthy CPU/NIU and ERM diagnostics, stable expansion I/O scanning and a controlled point test on the remote rack.
Recommended Models
| PH-3A-HG | EN60669-2-1 | 6ES7331-7NF00-0AB0 |
| 4FD5183-0AB20-1A | K1241 | AC2411 |
| V-U0048 | KA57 DRN90L4/BE2/TH | Vogel SK 200 305291 |
| DW-AS-509-M18-320 | M300-AD4 | C65-MW-K LNL-C65-MW-K |
| 1GR5 | ABB DX571 1TNE968902R2302 | ir425/ir425-D4-2 |
| 802T-DD | SW 030 8020950 | X20 AO 4622 Rev.N0 |
| MBS 1750 060G6109 | NET-400 | SMC5500/S |
| FM71 21.71.304 | 6DS1717-8CC | Tecsis P3297B081101 |
| WMS-117-322 | MI-DCMOE | 3-LRMF |
| ECP34 1L4 | 0371084 PGN-plus 40-IS | A16B-2203-0031/02B |