Connects the remote VersaMax I/O station to the PROFINET IO Controller.
Product Overview
IC200PNS001-AC is a VersaMax PROFINET Scanner module for interfacing a remote VersaMax modular I/O node with a PROFINET IO Controller. The PNS001 base model uses two RJ45 copper Ethernet connectors.
The AC suffix should remain on the replacement label. Device name, network configuration, controller project and the installed VersaMax module map must be retained before exchange.
Performance
Provides two copper RJ45 Ethernet connections for the documented PROFINET node.
Transfers the configured local I/O image between the VersaMax station and controller.
Supports modular station maintenance when device identity and slot order are preserved.
Technical Details
| Manufacturer | Emerson / legacy GE Fanuc |
|---|---|
| Exact model | IC200PNS001-AC |
| Platform | VersaMax Modular I/O |
| Product type | PROFINET Scanner module |
| Network role | Remote I/O node interface to a PROFINET IO Controller |
| Ethernet interface | Two RJ45 copper connectors |
| Station scope | Configured VersaMax module set and slot order |
| Hardware revision | AC |
| Selection basis | Complete label, controller project and station hardware record |
System Integration
- Archive the PROFINET device name, IP settings, controller hardware configuration and complete VersaMax slot map.
- Label both Ethernet paths and record switch ports, topology and media before removal.
- Confirm carrier and local module order exactly match the controller project before energizing the replacement.
- Assign the approved device identity and verify controller connection, diagnostics and every remote I/O module.
Applications
- Remote VersaMax I/O stations connected to a PROFINET IO Controller.
- Machine and process skids using copper Ethernet links for distributed I/O.
- Legacy station replacement where AC revision, device name and module map remain controlled.
FAQ
What project data should accompany an IC200PNS001-AC enquiry?
Provide the controller project, device name, IP settings, module-slot map, network topology and complete AC revision label.
Can IC200PNS001-AC replace IC200PNS002?
No direct equivalence should be assumed: PNS001 uses copper RJ45 interfaces while PNS002 is the fiber-interface execution.
Why can a correct IC200PNS001-AC still remain offline after installation?
A mismatched PROFINET device name, IP assignment, controller configuration, slot order or network path can prevent connection.
What network evidence helps diagnose IC200PNS001-AC faults?
Record link state on both ports, switch-port status, topology, duplicate-name or IP alarms and controller diagnostics.
What acceptance test should follow IC200PNS001-AC replacement?
Verify controller connection, station diagnostics and live input and output behavior for every configured VersaMax module.
About IndustryParts
https://www.industryparts.com/Network identity and station configuration travel together
IndustryParts handles IC200PNS001-AC with its AC revision, PROFINET identity, copper topology and complete module map.
- AC revision retained
- Device name archived
- Station map verified
Recommended Models
| SP3- GT35 | OAC808.9-1 | 1606-XLS480EE |
| H-4WEH 32 HE63/6EG24N9K4 R900943121 | MGFAS2-DSM-DSC-B/ECR | FI25/0.03-4 |
| 6SL3054-0ED00-1BA0 | DGD 1000-7 3029 | WE77/Ex-2 230V |
| SVCDS-P 70-400-1-230 21800003 | SEW K37 DRS71S4/MM03/TH | SH11C109200004 |
| C60Z 6D77305A11HPW | Pilz PZA 300/24VDC | RWX62.7034 |
| DNC-50-90-PPV-A | CI410 | O3PL0054004 F22028 |
| ABB CAL19-11 1SFN010820R1011 | 3RT1066-6AP36 | 6RA2491-4DV62-0 |
| 837447005 737 839-001 G00 | 1FK6042-6AF71-1GB0 | SEW 8221049.16 |
| PT 4-EX(I)-24DC-ST | 3TK2821-2CB30 | IC693MDL742D |
| HDL-MGSM.431 | 4I4O ZC H142402 | SP 140S-MC1-10-1K1-2K |