EIGHT ANALOG OUTPUTS · CURRENT OR VOLTAGE · REVISION CF
Emerson IC693ALG392-CF Series 90-30 Analog Output Module
A configurable analog output module whose range, field power and channel wiring are selected per point.
Product Identification
IC693ALG392-CF provides eight single-ended analog output channels for a Series 90-30 or supported RX3i system. Each point can be configured independently for voltage or current service; the default range is 0 to +10 V.
Available modes are 0 to +10 V, −10 to +10 V, 0 to 20 mA and 4 to 20 mA. A user 24 VDC source powers the field side, and the removable 20-terminal connector separates current and voltage output terminals for every channel.
Engineering Data
Functions
Per-channel range choice
One module can serve a controlled mixture of voltage and current loops when every terminal is mapped correctly.
Separate field paths
Dedicated voltage and current terminals keep the selected signal path explicit at the connector.
Loop-oriented status
Current-mode overload or open-wire status supplements module-health and field-power reporting.
Software configuration
Ranges are selected in the controller hardware configuration rather than by onboard jumpers.
About IndustryParts
https://www.industryparts.com/Exact identity before quotation
IndustryParts prepares IC693ALG392-CF enquiries around the complete manufacturer label, requested quantity and destination. For controlled replacements, include the host-system record, field photographs and configuration evidence that apply to this exact execution.
Applications
Final-control references
Sending 4–20 mA commands to positioners, drives or other receiving devices.
Analog setpoints
Providing unipolar or bipolar voltage references to compatible equipment.
Mixed signal cabinets
Consolidating eight separately configured current and voltage outputs with a documented common scheme.
Lifecycle
Archive
Save hardware configuration, %AQ mapping, channel ranges, scaling and failsafe behavior.
Trace
Identify the 24 VDC source, V COM, I COM and every voltage or current terminal before removal.
Prove
Measure each commanded output with a suitable load and verify loop response across the configured range.
FAQ
Q01
Can one IC693ALG392-CF channel produce voltage and current simultaneously?
+
No. Each channel is configured and wired for one output mode at a time.
Q02
What must be included with an IC693ALG392-CF enquiry?
+
Provide the CF label, baseplate slot, PAC Machine Edition configuration, %AQ map, eight ranges and the field-power drawing.
Q03
Why does IC693ALG392-CF need an external 24 VDC source?
+
The user supply powers the field output circuitry and forms part of the current-return and status-monitoring path.
Q04
Which IC693ALG392-CF diagnostics apply only in current mode?
+
Overload and open-wire detection are reported for current outputs; module health and user-power status cover all ranges.
Q05
How should IC693ALG392-CF be accepted after replacement?
+
Command low, mid and high values on every channel, measure the actual output and confirm the receiving loop responds with correct scaling.
Send the complete IC693ALG392-CF label, requested quantity and destination.