  • Product NameEmerson IC693MDL940J Series 90-30 Relay Output Module
  • Item NO.3809426
  • Weight0.4000 kg = 0.8818 lb = 14.1096 oz
  • CategoryDCS
  • BrandEmerson
  • Creation Time2026-10-26
Emerson IC693MDL940J Series 90-30 Relay Output Module
Series 90-30PRODUCT RECORD

REVISION J · FOUR ISOLATED OUTPUT BANKS · NORMALLY-OPEN CONTACTS

Emerson IC693MDL940J Series 90-30 Relay Output Module

A sixteen-point Series 90-30 relay module whose revision, group commons and connected-load record must remain together.

Channel layout4 banks × 4 points
Contact stateNormally open
Fuse arrangementExternal
01
PRODUCT CONTEXT

Overview

IC693MDL940J supplies sixteen normally-open relay outputs in four isolated groups of four. Each group has its own common, allowing the panel designer to separate documented load circuits instead of placing all points on one shared return.

The contacts support suitable AC or DC loads within the published Series 90-30 limits. Revision J is part of the installed identity; it should be recorded with the baseplate position, terminal assembly and field protection before a spare is approved.

02
CONTROLLED DATA

Specifications

Manufacturer
Emerson / GE Fanuc
Exact model
IC693MDL940J
Platform
Series 90-30
Output points
16 normally-open relay outputs
Electrical grouping
Four groups of four outputs
Common connections
One common per four-point group
Nominal field voltage
24 VDC or 120/240 VAC
Published operating range
5 to 30 VDC; 5 to 250 VAC, 50/60 Hz
Pilot-duty load
2 A maximum per output
Group common current
4 A maximum
Minimum load
10 mA
Maximum inrush
5 A
Switching time
15 ms maximum on or off
Isolation to logic
1500 V
Isolation between groups
500 V
Onboard output fuses
None
03
FUNCTIONAL PROFILE

Features

A

Four isolated banks

Separate commons make group-level power distribution and troubleshooting visible in the terminal schedule.

B

AC/DC contact flexibility

Relay contacts can serve suitable alternating- or direct-current loads after voltage and current checks.

C

Per-point status indication

Front indicators support local comparison with the PLC command and measured load state.

D

Revision-controlled identity

The J suffix stays linked to the installed module record rather than being dropped from procurement data.

IndustryParts industrial automation support
INDUSTRIAL PARTS SUPPORT

About IndustryParts

https://www.industryparts.com/

Exact identity before quotation

IndustryParts prepares IC693MDL940J enquiries around the complete manufacturer label, requested quantity and destination. For controlled replacements, include the host-system record, field photographs and configuration evidence that apply to this exact execution.

Complete labelRevision retainedApplication evidence
04
FIELD USE

Applications

Grouped actuator control

Operating contactors, solenoids or interposing devices across documented four-point banks.

Legacy rack maintenance

Replacing a Series 90-30 relay module while retaining the original baseplate and I/O assignment.

Mixed field circuits

Keeping independently protected AC or DC groups separated through their own commons.

05
SERVICE DISCIPLINE

Lifecycle

01

Map the banks

Record output addresses, four commons, load voltages, external fuses and suppression devices.

02

Transfer safely

Isolate every field source and move conductors under the approved terminal-by-terminal plan.

03

Exercise the loads

Command all sixteen points and verify the correct device, voltage and protective path for each bank.

06
CUSTOMER QUESTIONS

FAQ

Q01

Why is the J suffix important on IC693MDL940J?

It forms part of the installed hardware identity. Any revision change should be evaluated through the site change process, not assumed from visual similarity.

Q02

What should be checked when one IC693MDL940J output bank is inactive?

Inspect that bank’s common conductor, field source, external fuse, terminal assembly and load return before replacing the module.

Q03

Does IC693MDL940J include individual output fuses?

No. Branch and load protection are external and must be verified against the approved field design.

Q04

How should inductive loads on IC693MDL940J be documented?

Record steady current, inrush, switching rate and the AC or DC suppression method used to limit contact stress.

Q05

What acceptance record should follow an IC693MDL940J exchange?

Keep the point-by-point command results, group-common voltages, fuse status and updated terminal map with the maintenance record.