Emerson IC694ALG223-BB RX3i Analog Current Input Module

Emerson IC694ALG223-BB RX3i Analog Current Input Module

Item NO.: 3788608

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson IC694ALG223-BB RX3i Analog Current Input Module
  • Item NO.3788608
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandEmerson
  • Creation Time2026-10-11
PACSYSTEMS RX3I | CURRENT INPUT | BB HARDWARE REVISION

Emerson IC694ALG223-BB RX3i Analog Current Input Module

A BB-revision IC694ALG223 module for sixteen high-density single-ended current-input loops in an RX3i rack.

BrandEmerson / GE Fanuc
ModelIC694ALG223-BB
Product TypeRX3i 16-Channel Analog Current Input Module
01

Key Information

IC694ALG223-BB is the BB hardware execution of the PACSystems RX3i IC694ALG223 analog current input module. It brings sixteen single-ended process-current inputs into the controller and supports the documented 0–20 mA and 4–20 mA ranges.

The BB suffix is part of the installed identity and must not be dropped from a replacement request. Any revision-to-revision substitution still requires an approved rack, firmware and project compatibility check.

02

Functions

  • Connects sixteen single-ended analog current loops to PACSystems RX3i.
  • Supports 0–20 mA and 4–20 mA channel configurations.
  • Provides 12-bit field-signal conversion for controller processing.
  • Updates module data on the documented 13 ms schedule.
  • Consolidates high-density process inputs in one rack position.
03

Specifications

Manufacturer Emerson / GE Fanuc
Model IC694ALG223-BB
Base Catalog Number IC694ALG223
Hardware Revision BB
Product Family PACSystems RX3i
Product Type High-density analog current input module
Input Channels 16 single-ended
Input Ranges 0–20 mA and 4–20 mA
Resolution 12 bit
Module Update Time 13 ms
Backplane Current 120 mA at 5 VDC
User-Supplied Power 65 mA at 24 VDC
Agency Listing UL and UL hazardous-location listing
Approvals CE Zone 2, ATEX, Class I Division 2 and listed marine approvals
Mounting Context RX3i rack-based I/O installation
Revision Control BB suffix retained for sourcing and receiving
04

Installation

  • Save the channel configuration, scaling, alarm logic and controller references before removing IC694ALG223-BB.
  • Record the BB label, rack slot, terminal assembly, loop commons and external 24 VDC supply.
  • Use the site loop-isolation procedure and verify polarity before moving any conductor.
  • Load only the approved project configuration and confirm that the controller recognizes the installed hardware revision.
  • Calibrate each used loop and verify engineering values, alarms, interlocks and diagnostics.
05

Lifecycle

  • Store BB revision, calibration and project records with the module history.
  • Trend channel deviations and common loop-supply events across the sixteen inputs.
  • Inspect terminals, field power and shielding when proof-testing associated instruments.
  • Review manufacturer compatibility before moving from BB to FC or another hardware execution.
07

FAQ

Why must the BB suffix remain visible when ordering IC694ALG223-BB?

The suffix identifies the installed hardware execution and lets engineering compare revision support, rack history and the validated project before approving another unit.

What should be recorded from the IC694ALG223-BB terminal assembly?

Capture wire numbers, channel positions, commons, shields, loop power, terminal part identity and clear photographs before disconnection.

How can an IC694ALG223-BB fault be separated from a field-loop fault?

Use a traceable current source at the terminal, verify external 24 VDC and wiring continuity, compare raw data and diagnostics, and test the field transmitter separately.

What commissioning evidence is expected after an IC694ALG223-BB change?

Retain as-left labels, project checksum, current-injection results, scaled-value checks, alarms, interlocks and final loop restoration approval.

Can IC694ALG223-BB and IC694ALG223-FC be mixed in one spares pool?

Only after the site has documented manufacturer compatibility, controller and firmware support, terminal equivalence and a tested revision-control procedure.