Home>DCS>Emerson PR9268/203-100 Vertical Velocity Sensor

Hot Categories

Emerson PR9268/203-100 Vertical Velocity Sensor

Emerson PR9268/203-100 Vertical Velocity Sensor

Item NO.: 3786305

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameEmerson PR9268/203-100 Vertical Velocity Sensor
  • Item NO.3786305
  • Weight0.9300 kg = 2.0503 lb = 32.8048 oz
  • CategoryDCS
  • BrandEpro
  • Creation Time2026-10-09
EMERSON AMS | PR9268 | 10 M ARMORED OPEN-END CABLE

Emerson PR9268/203-100 Vertical Velocity Sensor

A vertical electrodynamic sensor with a 10 m armored open-end cable for absolute case-vibration measurement.

BrandEmerson
ModelPR9268/203-100
Product TypePR9268 Vertical Electrodynamic Velocity Sensor
01

Technical Summary

PR9268/203-100 is an Emerson mechanical velocity sensor for vertical mounting and absolute casing-vibration measurement. The /20 family operates over 4 to 1000 Hz and provides 28.5 mV/mm/s sensitivity.

The 3 ordering digit selects a 10 m armored cable; the 1 cable-end digit selects an open cable end. The complete suffix must be retained because cable construction and termination differ from other /20 variants.

02

Specifications

Manufacturer Emerson
Model PR9268/203-100
Measurement Absolute case vibration velocity
Orientation Vertical; ±30° without sinking current, ±60° with sinking current
Sensitivity 28.5 mV/mm/s (723.9 mV/in/s)
Frequency Range 4 to 1000 Hz
Natural Frequency 4.5 Hz ±0.75 Hz at 20°C
Operating Temperature -20 to +100°C (-4 to +212°F)
Cable 10 m, armored
Cable End Open cable end
Protection IP55
Housing Material Al Mg Si Pb F 28
Power Self-powered
Maximum Acceleration 10 g peak-to-peak continuous; 20 g intermittent
03

Features

  • Provides low-frequency case-vibration measurement down to 4 Hz.
  • Uses a ten-meter stainless-steel-armored cable for protected routing.
  • Offers an open cable end for direct termination in the approved junction or monitor circuit.
  • Supports vertical machinery locations within the specified inclination envelope.
04

Compatibility

  • Match monitor input sensitivity and engineering-unit scaling to 28.5 mV/mm/s.
  • Confirm vertical orientation, mounting surface and available armored-cable bend radius.
  • Verify terminal assignment, shield treatment, barrier data and hazardous-area approvals.
  • Do not substitute PR9268/207-100, whose ten-meter cable is non-armored.
05

Replacement

  • Record polarity, terminal numbers, shield bonding and channel settings before disconnection.
  • Support the armored cable so its mass does not preload the sensor.
  • Verify noise floor, polarity, scaling and alarm operation after installation.
06

FAQ

PR9268/203-100: What termination evidence should be supplied?

Provide terminal-strip photographs, conductor colors, shield connection, barrier or isolator model and the monitor input-card designation.

PR9268/203-100: How is it distinguished from PR9268/207-100?

Both have a ten-meter open-end lead, but PR9268/203-100 uses armored cable while PR9268/207-100 uses non-armored cable.

PR9268/203-100: What routing check is important for the armored lead?

Confirm minimum bend radius, mechanical support, hot-surface clearance and that cable weight cannot twist or bias the sensor.

PR9268/203-100: Can the existing channel scaling be reused automatically?

Only if the previous sensor sensitivity, polarity and monitor input configuration are documented as the same.

PR9268/203-100: What information reduces commissioning time?

Retain the previous baseline spectrum, overall velocity, polarity, alarm setpoints and a marked terminal drawing.

PR9268/203-100: What should a hazardous-area quotation state?

It should identify the exact approval option, compatible interface equipment, cable termination scope and required certificates rather than relying on the family name alone.

You May Also Like