Fuji Electric ZAF3K404-MYAAA-YEAYY Thermal Conductivity Gas Analyzer

Fuji Electric ZAF3K404-MYAAA-YEAYY Thermal Conductivity Gas Analyzer

Item NO.: 3787771

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameFuji Electric ZAF3K404-MYAAA-YEAYY Thermal Conductivity Gas Analyzer
  • Item NO.3787771
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • Brandothers
  • Creation Time2026-10-10
ZAF-3 GAS ANALYZER | THERMAL CONDUCTIVITY | LEGACY CONFIGURATION

Fuji Electric ZAF3K404-MYAAA-YEAYY Thermal Conductivity Gas Analyzer

A complete legacy ZAF-3 configuration identifier for continuous industrial gas concentration measurement.

BrandFuji Electric
ModelZAF3K404-MYAAA-YEAYY
Product TypeZAF-3 Thermal Conductivity Gas Analyzer
01

Product Profile

ZAF3K404-MYAAA-YEAYY identifies a Fuji Electric ZAF-3 thermal-conductivity gas analyzer configuration. The ZAF family measures gas concentration continuously by comparing heat loss from platinum elements in measuring and reference-gas chambers.

The submitted suffix is retained without speculative decoding. The measured gas, reference gas, range, output, power and optional functions must be read from the analyzer label or configuration documents. Fuji Electric lists ZAF-3 as discontinued, with ZAF-4 as the designated substitute family.

02

Technical Data

Manufacturer Fuji Electric
Model ZAF3K404-MYAAA-YEAYY
Product Family ZAF-3 thermal conductivity gas analyzer
Measurement Principle Thermal conductivity using platinum-wire bridge elements
Measurement Mode Continuous gas concentration measurement
Display Family Digital concentration indication
Possible ZAF Gas Services Hydrogen, helium, argon, methane or carbon dioxide depending on configuration
Signal Outputs Analog output execution determined by the complete suffix and label
Reference Gas Defined by the configured measurement application
Installation Context Indoor panel or instrument installation as defined for the analyzer execution
Calibration Requirement Zero and span gases must match the configured gas and range
Lifecycle Status ZAF-3 discontinued September 2013
Successor Family ZAF-4, subject to application and dimensional review
Critical Ordering Data Full suffix, measured gas, reference gas, range, output, power and options
03

System Role

  • Compares thermal conductivity of sample and reference gases to derive concentration.
  • Provides a continuous analyzer signal for the configured process-gas range.
  • Supports alarm, recording or control integration through the configured output execution.
  • Requires application-specific zero and span calibration gases.
04

Compatibility

  • Preserve the complete ZAF3K404-MYAAA-YEAYY suffix rather than selecting only by the ZAF-3 family name.
  • Record sample pressure, flow conditioning, moisture control and reference-gas arrangement.
  • Match analog output, power supply and any serial or calibration options.
  • Treat ZAF-4 as a migration project that requires range, piping, panel and signal review.
05

Applications

  • Hydrogen concentration monitoring in process and energy applications.
  • Configured helium, argon, methane or carbon-dioxide measurements where thermal conductivity provides adequate selectivity.
  • Replacement planning for installed ZAF-3 analyzer panels.
06

FAQ

What must be supplied to quote ZAF3K404-MYAAA-YEAYY accurately?

Provide the complete nameplate, measured and reference gases, range, analog output, power supply, options, panel cutout and sample-system details.

Can a ZAF-4 replace ZAF3K404-MYAAA-YEAYY without panel or process changes?

Not automatically. Compare gas service, range, response, output, power, dimensions, piping and calibration requirements before migration.

How should calibration gas be selected for ZAF3K404-MYAAA-YEAYY?

Use the gas composition and concentration specified for the exact analyzer range and process background; unsuitable mixtures can create a systematic error.

What process conditions can make ZAF3K404-MYAAA-YEAYY read incorrectly even when calibration is valid?

Unexpected background gases, moisture, pressure or flow changes, contamination and sample leaks can alter thermal conductivity at the measuring cell.

Which records should be preserved before removing ZAF3K404-MYAAA-YEAYY?

Save analyzer settings, zero/span results, sample-system drawings, output scaling, alarm settings and clear photographs of every terminal and tube connection.