Lenze E84AYCERV/S PROFINET Communication Module
A PROFINET RT communication module for integrating Lenze 8400 drives into an industrial Ethernet network.
Product Profile
E84AYCERV/S is the Lenze PROFINET communication module for compatible 8400 inverter drives. It operates as a PROFINET device and provides cyclic process-data exchange with the controller.
Replacement requires the device name, IP configuration, process-data mapping and matching drive firmware to be preserved.
Technical Data
| Manufacturer | Lenze |
|---|---|
| Complete Model | E84AYCERV/S |
| Product Family | 8400 communication modules |
| Network | PROFINET RT |
| Conformance Class | Class B |
| Device Role | PROFINET slave / device |
| Data Rate | 100 Mbit/s |
| Physical Medium | CAT5e S/FTP Ethernet |
| Topology | Line topology supported |
| Logical Process-Data Channels | 1 |
| Process Data | 1 to 16 words of 16-bit process data |
| Maximum Cable Length Between Nodes | 100 m |
System Role
- Connects a compatible 8400 drive to a PROFINET RT controller.
- Two-port line topology simplifies daisy-chain cabinet networking.
- Cyclic process data supports command, setpoint, status and actual-value exchange.
- Diagnostic information helps separate network, controller and drive faults.
Compatibility
- Confirm the host 8400 drive series and supported communication slot.
- Use the correct GSDML file and controller engineering version.
- Match process-data word count and byte order to the existing PLC program.
Applications
- PROFINET integration of Lenze 8400 drives in automated machinery.
- Replacement of a documented communication module with preserved network identity.
- Drive-network modernization where controller configuration and process data remain controlled.
FAQ
Can E84AYCERV/S be installed in any Lenze drive?
No. Confirm the compatible 8400 host, communication slot and firmware before installation.
What network data must be saved before replacing E84AYCERV/S?
Record the PROFINET device name, IP settings, topology, GSDML version and process-data mapping.
Does E84AYCERV/S operate as a PROFINET controller?
No. It is a PROFINET device that exchanges data with the upstream controller.
How much process data can E84AYCERV/S exchange?
The documented module supports one logical channel with 1 to 16 words of 16-bit process data.
Why can a correct E84AYCERV/S still fail to communicate after replacement?
An unmatched device name, controller configuration, topology, firmware or process-data mapping can prevent data exchange.
What acceptance test should follow E84AYCERV/S installation?
Check link and device diagnostics, controller connection, command and status words, setpoints, actual values and machine interlocks.
Recommended Models
| X20BC00E3 | FS21226-75-34 | X20CM8281 |
| GLV12-6/36/40b/115 | 253-TALW-LAHG-C5-BD | MJ100 |
| 73091C | 3A99266G01 | AT352 |
| MCS 09H60-EQIB0-A14N-ST5S00N-R0SU | XY2CH13270 | ABB 6197/52-101-500 |
| 7KT1662 | 110100501 | Sauter EYF3 A355 CL367211/001 |
| REF 2424 | RK40 RK 40-24H | 6ES7422-1HH00-0AA0 |
| EW100 EM100 | C40S-1803CA010 1018655 | 6GK7342-5DA03-0XE0 |
| TSX DET 3212 082733 | 9506/11-00 | 6ES7 322-1BH10-0AA0 |
| Siemens 1LA91892WA99-ZN60 | 0-900-69-459-8 GI357.Z54 | TD3RCBO |
| NNTN8191C | I-7520 RS-232 RS-485 | Nord SK 672.1-132MP/4 |