  • Product NamePepperl+Fuchs KCD2-STC-Ex1 One-Channel SMART Transmitter Power Supply
  • Item NO.3804108
  • Weight0.1500 kg = 0.3307 lb = 5.2911 oz
  • CategoryPLC
  • Brandothers
  • Creation Time2026-10-22
K-System Isolated BarriersKCD2-STC-Ex1
ONE INTRINSICALLY SAFE CHANNEL · SOURCE/SINK/VOLTAGE OUTPUT · 12.5 MM

Pepperl+Fuchs KCD2-STC-Ex1 One-Channel SMART Transmitter Power Supply

A 12.5 mm one-channel isolated barrier for powering two-wire SMART transmitters and transferring 4–20 mA with bidirectional communication.

01

Product Overview

product overview

Pepperl+Fuchs KCD2-STC-Ex1 is a one-channel isolated barrier for supplying two-wire SMART transmitters or accepting two-wire SMART current sources in hazardous-area applications.

The device transfers the analog value to the safe side and supports bidirectional superimposed digital communication. DIP switches select 4–20 mA source, 4–20 mA sink or 1–5 V output operation.

The narrow 12.5 mm housing mounts on a 35 mm DIN rail and can receive 24 V DC from the Power Rail or its supply terminals.

02

Performance

performance
CONTROL POINT

Intrinsic-safety separation

Interfaces the hazardous-area transmitter circuit with the safe-area control system.

CONTROL POINT

SMART communication

Transfers superimposed digital communication bidirectionally across the barrier.

CONTROL POINT

Power Rail integration

Uses centralized 24 V DC distribution while preserving the narrow channel density.

03

Technical Details

technical details
Manufacturer
Pepperl+Fuchs
Exact model
KCD2-STC-Ex1
Signal type
Analog input
Channels
1
Supply
19–30 V DC
Power connection
Power Rail or terminals 9+, 10−
Input
4–20 mA; limited to approximately 26 mA
Transmitter supply
At least 15 V at 20 mA
Output modes
4–20 mA source or sink; 1–5 V source
Source-mode load
0–350 Ω
Configuration
DIP switches
Functional safety
SIL 2; systematic capability SC 3
Degree of protection
IP20
Mounting
35 mm DIN rail
INDUSTRIAL AUTOMATION SUPPLY SUPPORT

About IndustryParts

https://www.industryparts.com/

Exact-model support for KCD2-STC-Ex1

IndustryParts keeps the complete KCD2-STC-Ex1 identity, requested quantity and installed-system evidence together so the proposed supply can be compared with the actual application before dispatch.

Revision boundary documented
Configuration evidence compared
Order identity preserved
IndustryParts industrial automation support team
04

System Integration

system integration
Confirm the exact Ex1 execution, certificate and loop entity parameters.

Record the required output mode and control-system input impedance.

Set the DIP switches before commissioning.

Wire the field, output and Power Rail or terminal supply using the documented terminal map.

Verify loop supply margin and 4–20 mA scaling.

Prove SMART communication and the required safe-state behavior before release.

05

Applications

applications

Suffix control

Keep the Ex1 suffix; non-Ex and dual-output versions have different selection boundaries.

Mode control

Record every DIP-switch position with the loop dossier.

Acceptance

Test analog transfer, communication and hazardous-area loop verification together.

06

FAQ

faq
Q01Why is the final “1” required in KCD2-STC-Ex1?

It identifies the documented one-channel Ex1 product; KCD2-STC-Ex is not the complete manufacturer model.

Q02Which output modes can KCD2-STC-Ex1 provide?

DIP switches select 4–20 mA source, 4–20 mA sink or 1–5 V source operation.

Q03What control-side information is needed for a KCD2-STC-Ex1 enquiry?

Provide the required output mode, input resistance, supply method, loop drawing and existing switch settings.

Q04Can KCD2-STC-Ex1 be chosen from the 4–20 mA range alone?

No. The hazardous-area approval, transmitter supply requirement, output mode and load must all be verified.

Q05What belongs in the KCD2-STC-Ex1 commissioning record?

Include entity verification, switch positions, loop supply margin, low/high current checks, SMART communication and final diagnostics.