Home>PLC>Siemens 6AU1445-0AA00-0AA1 SIMOTION D445-1 Motion Controller

Hot Categories

Siemens 6AU1445-0AA00-0AA1 SIMOTION D445-1 Motion Controller

Siemens 6AU1445-0AA00-0AA1 SIMOTION D445-1 Motion Controller

Item NO.: 3745879

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6AU1445-0AA00-0AA1 SIMOTION D445-1 Motion Controller
  • Item NO.3745879
  • Weight3.6000 kg = 7.9366 lb = 126.9863 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-08-24
  • SIMOTION D445-1 Motion Controller
Siemens 6AU1445-0AA00-0AA1 SIMOTION D445-1 Motion Controller | HTML Preview

Siemens 6AU1445-0AA00-0AA1 SIMOTION D445-1 Motion Controller


ManufacturerSiemensModel6AU1445-0AA00-0AA1Product TypeSIMOTION D445-1 Motion Controller

01Technical Summary

Siemens 6AU1445-0AA00-0AA1 is a SIMOTION D445-1 programmable motion controller in the high-performance class. It is a legacy spare-part article for machines combining PLC, motion, and SINAMICS drive-control tasks. Siemens identifies this article as discontinued and deleted without a stated direct replacement, so procurement and migration must be controlled against the installed project.

Configuration ControlMatch the complete Siemens article number, installed system, hardware revision, interfaces, software and firmware, wiring, project, approvals, and lifecycle plan before ordering or replacement.

02Applications

Typical Uses

  • High-performance multi-axis machines originally engineered around the SIMOTION D445-1 platform.
  • Coordinated positioning, gearing, camming, interpolation, and technology control with SINAMICS drives.
  • PROFIBUS-based distributed automation combined with DRIVE-CLiQ drive topology.
  • Legacy spare-part replacement where the exact controller revision, memory card, software, and project are retained.
  • Lifecycle planning for machines that cannot yet be migrated to a current automation architecture.

Selection Boundary

  • Use application examples only as engineering context; they do not prove compatibility with an installed machine.
  • Confirm electrical, mechanical, network, software, safety, environmental, and lifecycle requirements against the complete project.
  • Preserve configuration records and perform controlled commissioning whenever hardware is exchanged.

03Specifications

Manufacturer Siemens
Article Number 6AU1445-0AA00-0AA1
Product Name SIMOTION D445-1
Performance Class High performance
Maximum Axes 64
Digital Inputs 8
Configurable Digital I/O 8 DI/DO
DRIVE-CLiQ Interfaces 6
PROFIBUS Interfaces 2
Industrial Ethernet Interfaces 2
USB Interfaces 2
Option Slot 1
Minimum Software Baseline SIMOTION V4.1 SP2 HF3/HF4 or later as documented
Included Service Hardware Dual fan/battery module and battery
Lifecycle Status Product Discontinued; cancelled/deleted without replacement

04Features

Design and Functions

  • High-performance D445-1 controller class documented for configurations with up to 64 axes.
  • Combines motion, PLC, technology, and drive-control execution in the SIMOTION D architecture.
  • Six DRIVE-CLiQ interfaces support the documented SINAMICS system topology.
  • Two PROFIBUS and two Industrial Ethernet interfaces provide field and service connectivity.
  • Eight digital inputs and eight configurable digital input/output channels support local machine signals.
  • Two USB interfaces and one option slot are present; optional communication capability depends on the installed board and project.

Product Identity

  • Manufacturer: Siemens
  • Model: 6AU1445-0AA00-0AA1
  • Product Type: SIMOTION D445-1 Motion Controller
  • Lifecycle: Product Discontinued

05Compatibility

  • Match the complete 6AU1445-0AA00-0AA1 article and do not collapse it with a D445-2, D455, or another hardware revision.
  • Confirm the controller firmware, SIMOTION software release, CompactFlash card, licenses, technology packages, and option board.
  • Preserve PROFIBUS addresses, Industrial Ethernet settings, telegrams, DRIVE-CLiQ topology, and drive firmware.
  • Verify the dual fan/battery module, 24 V supply, connector keying, grounding, shielding, and cabinet cooling.
  • Because Siemens states no replacement for this article, any platform change must be treated as a full engineered migration.
  • Validate obsolete option modules and field devices separately because a controller-only comparison does not prove system compatibility.

06Maintenance & Replacement

  • Create verified backups of the project, card contents, licenses, drive parameters, safety data, and commissioning records.
  • Record hardware and firmware versions, option board, axis and drive assignments, fieldbus settings, I/O wiring, and machine-specific technology parameters.
  • Inspect the fan/battery module and keep a controlled record of battery replacement and cabinet thermal condition.
  • After exchange, verify startup, memory-card recognition, project consistency, communication, axes, encoders, limits, alarms, interlocks, and safety functions.
  • Run reference, low-speed, synchronized-motion, and controlled production tests before release.
  • Maintain a migration plan because the official lifecycle record identifies the article as discontinued without replacement.

FAQFrequently Asked Questions

What is 6AU1445-0AA00-0AA1?

6AU1445-0AA00-0AA1 is a discontinued high-performance SIMOTION D445-1 programmable motion controller for legacy multi-axis machines.

Where is this product normally used?

It is used in machines combining high-performance motion control, PLC logic, and SINAMICS drive coordination.

What must be checked before ordering?

Confirm the complete article number, installed hardware revision, lifecycle state, supply and I/O design, communication interfaces, connector assignment, software release, approvals, and project configuration.

What information should be saved before replacement?

Save the complete project and card image, licenses, firmware, option module, fieldbus settings, drive topology, axes, I/O, safety records, and validated commissioning data.

Can a similar Siemens article be used as a direct replacement?

No direct replacement is stated by Siemens. A different SIMOTION or automation controller requires an engineered migration and complete machine validation.

What should be verified after installation?

Verify project and card recognition, communication, all axes, encoders, brakes, limits, I/O, alarms, interlocks, safety functions, and the full machine process.

You May Also Like