Differential acquisition
Measures the process signal relative to the documented paired input connection.
Warranty: 1 year
Condition : brand new in factory sealed box
Email: sales@mvme.cn
Chat online: +86 18030175807
A single-channel differential analog input signal board for voltage or current measurement at the S7-1200 CPU front.
6ES7231-4HA30-0XB0 is the SB 1231 analog input signal board for SIMATIC S7-1200. It converts one differential voltage or current signal into a controller process value without adding a separate signal module.
Current measurement uses the documented terminal link between R and 0+, while voltage measurement follows a different input path. The chosen mode, sensor supply, polarity, shielding and scaling must remain in the channel record.
Siemens
6ES7231-4HA30-0XB0
SB 1231, AI 1x12 bit
1 differential channel
−10 V to +10 V
0 to 20 mA
24 V DC
55 mA typical
0.4 W typical
156.25 µs at 400 Hz suppression
100 m maximum
38 × 62 × 21 mm
Measures the process signal relative to the documented paired input connection.
Accepts the supported voltage or current circuit with mode-specific wiring.
Adds one analog input without changing the CPU mounting envelope.
Provides the published conversion performance for responsive process acquisition.
IndustryParts prepares 6ES7231-4HA30-0XB0 enquiries around the complete manufacturer label, requested quantity and installed-system evidence. Share the application record that distinguishes this execution before a supply proposal is prepared.
Identify the installed voltage or current circuit before moving conductors to 6ES7231-4HA30-0XB0.
Retain the installed host, project and connection evidence that defines the approved use of this execution.
Complete the model-specific checks described in the service sequence before return to operation.
Reading a compatible current-loop signal with the documented terminal link and supply.
Acquiring a differential voltage signal within the configured range.
Restoring channel mode, scaling and shield arrangement after service.
Provide the CPU article number, complete board label, signal type, sensor supply, range, terminal map and quantity.
No. Use the specified S7-1200 temperature-input board when those sensor types are required.
It is part of the documented current-input terminal arrangement; omitting or misplacing it changes the measurement path.
Save scaling, filter, diagnostic state, polarity, conductor markers and stable reference readings.
Retain multi-point signal results, correct engineering scaling, stable diagnostics and completed process-response tests.
Send the complete 6ES7231-4HA30-0XB0 label, requested quantity and delivery destination.