Siemens 6ES7513-1FL02-0AB0 SIMATIC S7-1500F CPU 1513F-1 PN
A fail-safe S7-1500F CPU with 450 KB program memory, 1.5 MB data memory and one PROFINET IRT interface.
Product Overview
6ES7513-1FL02-0AB0 is the fail-safe CPU 1513F-1 PN, not the standard CPU 1513-1 PN. Siemens lists 450 KB program memory and 1.5 MB data memory for this F execution.
The CPU uses a PROFINET IRT interface with a two-port switch, provides 40 ns bit performance and requires a SIMATIC Memory Card.
Replacement work must preserve both the standard and safety portions of the approved project, including F-signatures, access protection and proof-test evidence.
Performance
Execute standard and fail-safe logic
Runs the approved S7-1500F application within the configured safety lifecycle.
Coordinate PROFINET I/O
Maintains the engineered IRT topology and approved F-I/O communication.
Protect safety identity
Uses project and access controls that must remain traceable through service.
Technical Details
| Manufacturer | Siemens | Exact model | 6ES7513-1FL02-0AB0 |
|---|---|---|---|
| Product designation | CPU 1513F-1 PN | Controller class | Fail-safe S7-1500F CPU |
| Program work memory | 450 KB | Data work memory | 1.5 MB |
| Bit performance | 40 ns | Primary interface | PROFINET IRT with two-port switch |
| Memory card | SIMATIC Memory Card required | Selection boundary | Approved F-project and safety lifecycle |
System Integration
Freeze the safety record
Archive the complete project, F-signature, firmware, access settings and proof-test status.
Capture the network
Record PROFINET names, addresses, topology and every configured F-I/O station.
Install under authorization
Match the exact F-CPU article and approved engineering environment before download.
Complete validation
Run the safety-function tests required by the plant validation plan and retain the results.
Applications
Fail-safe machine control
Executing standard and safety logic in an approved S7-1500F architecture.
F-I/O coordination
Maintaining configured PROFIsafe communication over the engineered PROFINET network.
Controlled CPU exchange
Replacing the F-CPU while preserving validated safety evidence.
FAQ
Q01Why must 6ES7513-1FL02-0AB0 not be confused with 6ES7513-1AL02-0AB0?+
The FL02 article is the fail-safe CPU 1513F-1 PN and has a different program-memory and safety-project boundary.
Q02What safety evidence should accompany a 6ES7513-1FL02-0AB0 enquiry?+
Provide the approved project, F-signature, firmware, SIMATIC Memory Card record, access settings and last proof-test evidence.
Q03Can the safety application be restored from hardware settings alone?+
No. The validated fail-safe project and authorized engineering procedure are required.
Q04What should be documented on the PROFINET side of 6ES7513-1FL02-0AB0?+
Record device names, topology, IRT settings and every configured standard and F-I/O station.
Q05What closes a 6ES7513-1FL02-0AB0 replacement record?+
Matching hardware and firmware, restored signatures, clean diagnostics and completed safety-function validation provide closure.
About IndustryParts
https://www.industryparts.com/Fail-safe CPUs remain linked to the validated safety record
IndustryParts keeps the exact F-CPU article, F-signature, project archive and requested quantity together for review.
- •Exact submitted model retained
- •Installed-system evidence reviewed
- •Requested quantity linked to the enquiry
Related Models
Request a model-specific quotation
Send the complete 6ES7513-1FL02-0AB0 label, requested quantity, delivery destination and installed-system context.