Siemens 6SL3000-0BE21-6AA0 SINAMICS S120 Wideband Line Filter
Wideband 380-480 V line filter engineered for the SINAMICS S120 16 kW Active Line Module.
01Product Identification
Siemens 6SL3000-0BE21-6AA0 is a SINAMICS S120 wideband line filter for the 16 kW Active Line Module. It is rated for 380 to 480 V three-phase systems, 47 to 63 Hz and 30 A, with approximately 170 W power loss. Wideband and basic line filters are not interchangeable labels: the connected line module, controller filter setting, network conditions and prescribed commissioning procedure must match the exact filter type.
02Engineering Data
| Manufacturer | Siemens |
|---|---|
| Article Number | 6SL3000-0BE21-6AA0 |
| Product Family | SINAMICS S120 |
| Product Type | Wideband line filter |
| Compatible Line Module | 16 kW Active Line Module |
| Input Voltage | 380 to 480 V AC, 3-phase |
| Voltage Tolerance | +10% / -10%; -15% for less than 1 minute |
| Line Frequency | 47 to 63 Hz |
| Rated Current | 30 A |
| Power Loss | 170 W |
| Lifecycle | Cancelled product; spare part |
03Functions
Operational Functions
- Attenuates line-side interference across a broad frequency range in the documented S120 configuration.
- Is assigned to the 16 kW SINAMICS S120 Active Line Module.
- Handles 30 A rated current on 380 to 480 V three-phase networks.
- Supports an engineered EMC installation when used with prescribed wiring, grounding and shield practices.
- Requires the controller parameter setting that corresponds to the selected filter type.
- Works as part of the line connection rather than as a standalone power-conversion device.
Identification
- Manufacturer: Siemens
- Model: 6SL3000-0BE21-6AA0
- Product Type: SINAMICS S120 wideband line filter for 16 kW Active Line Module
- Status: Cancelled product; spare part
04Applications
Use Cases
- SINAMICS S120 systems using a 16 kW Active Line Module and specified wideband filtering.
- Machine cabinets that require the exact 6SL3000-0BE21-6AA0 line-side component.
- Maintenance replacement where cable routing, grounding and filter setting are retained.
- Drive retrofits that preserve the documented line-module and filter pairing.
- EMC-sensitive industrial installations engineered to Siemens S120 guidance.
Compatibility Boundary
- Use with the documented 16 kW Active Line Module and the exact wideband-filter configuration.
- Confirm line voltage, frequency, rated current, upstream protection and conductor sizing.
- Set the drive or controller parameter for the correct filter type before running identification.
- Perform line-supply and DC-link identification where required by the Siemens commissioning instructions.
- Maintain short, low-inductance grounding and the prescribed shield and cable routing.
- Do not substitute 6SL3000-0BE21-6DA0 merely because both articles serve a 16 kW-class system.
05Lifecycle
- Siemens identifies 6SL3000-0BE21-6AA0 as a cancelled spare-part article.
- Confirm current spare-part availability and the exact supported migration path before planning a retrofit.
- Record the connected line-module article, filter parameters, network data and physical installation.
- A different filter requires electrical, EMC, parameter and commissioning review.
- After replacement, verify precharge, line current, DC-link identification, fault-free operation and EMC performance.