Home>PLC>Siemens 6SL3040-1MA01-0AA0 CU320-2 PN Control Unit

Hot Categories

Siemens 6SL3040-1MA01-0AA0 CU320-2 PN Control Unit

Siemens 6SL3040-1MA01-0AA0 CU320-2 PN Control Unit

Item NO.: 3804082

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6SL3040-1MA01-0AA0 CU320-2 PN Control Unit
  • Item NO.3804082
  • Weight2.2000 kg = 4.8502 lb = 77.6027 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-10-22
SINAMICS S120CONTROLLED PRODUCT RECORD
PROFINET CONTROL UNIT · MULTI-AXIS SINAMICS S120 · NO COMPACTFLASH CARD

Siemens 6SL3040-1MA01-0AA0 CU320-2 PN Control Unit

An active CU320-2 PN control unit for SINAMICS S120 multi-axis systems, supplied without its required CompactFlash card.

01

Key Information

key information

Siemens 6SL3040-1MA01-0AA0 is the SINAMICS S120 CU320-2 PN control unit for coordinating modular multi-axis drive systems over PROFINET. It provides the central control, topology and commissioning functions for connected SINAMICS components.

The article is supplied without a CompactFlash card. Firmware, licenses and the approved drive project therefore remain separate controlled items and must match the installed system.

Replacement planning should retain the full PROFINET configuration, DRIVE-CLiQ topology, option-module assignment and machine safety validation rather than treating the control unit as a blank plug-in spare.

02

Functions

functions
CONTROL POINT

Central drive coordination

Runs the control and coordination tasks for the configured SINAMICS S120 drive topology.

CONTROL POINT

PROFINET integration

Connects the drive system to the plant automation network through the PN execution.

CONTROL POINT

DRIVE-CLiQ management

Identifies and exchanges data with compatible drive components across four DRIVE-CLiQ interfaces.

INDUSTRIAL AUTOMATION SUPPLY SUPPORT

About IndustryParts

https://www.industryparts.com/

Exact-model support for 6SL3040-1MA01-0AA0

IndustryParts keeps the complete 6SL3040-1MA01-0AA0 identity, requested quantity and installed-system evidence together so the proposed supply can be compared with the actual application before dispatch.

Exact label retained
Installed-system evidence reviewed
Packing record kept traceable
IndustryParts industrial automation support team
03

Specifications

specifications
Manufacturer
Siemens
Exact model
6SL3040-1MA01-0AA0
Product family
CU320-2 Control Unit
Product designation
CU320-2 PN
Industrial network
PROFINET
DRIVE-CLiQ interfaces
4
Digital inputs
12
CompactFlash card
Not included
Lifecycle
PM300 active product
Packaging dimensions
50 × 226 × 300 mm
Operating temperature
0 to 55 °C
Installation altitude
Up to 2000 m
04

Installation

installation
BEFORE

Archive the drive project, firmware, licenses and PROFINET identity.

Record every DRIVE-CLiQ node, option board, I/O assignment and safety function.

FIT

Select the correct CompactFlash card separately.

Restore the approved topology and network settings before enabling the axes.

VERIFY

Compare actual and configured DRIVE-CLiQ topologies.

Complete axis, network, diagnostic and machine-safety acceptance tests.

05

Lifecycle

lifecycle

Active identity

Siemens lists the exact article as an active CU320-2 product.

Card dependency

The bare control unit does not include the CompactFlash card needed for the system execution.

Migration control

Hardware generation, firmware, power modules and project requirements must be reviewed together.

07

FAQ

faq
Q01

Does 6SL3040-1MA01-0AA0 include its CompactFlash card?

No. Siemens lists 6SL3040-1MA01-0AA0 without the CompactFlash card, so the correct card, firmware and licenses must be selected separately.

Q02

What project evidence should accompany a 6SL3040-1MA01-0AA0 enquiry?

Provide firmware, CompactFlash identity, PROFINET name and addressing, DRIVE-CLiQ topology, option boards and configured axes.

Q03

Can 6SL3040-1MA01-0AA0 replace the original CU320 without engineering review?

No. The CU320-2 generation, card, firmware and connected-component compatibility must be checked before migration.

Q04

What is the main network boundary for 6SL3040-1MA01-0AA0?

It is the PN execution; preserve the approved PROFINET device identity, controller relationship and network diagnostics.

Q05

What proves 6SL3040-1MA01-0AA0 is ready after replacement?

Confirm the restored project, all DRIVE-CLiQ nodes, PROFINET communication, axis operation, diagnostics and machine safety functions.