Siemens 6SL3130-1TE22-0AA0 SINAMICS S120 Basic Line Module 20 kW
A 20 kW internally air-cooled supply module that converts a 380–480 V three-phase input into the shared 600 V DC link of a SINAMICS S120 line-up.
Technical Summary
6SL3130-1TE22-0AA0 is the 20 kW Basic Line Module in this SINAMICS S120 booksize range. It accepts the industrial three-phase line supply and provides a rated 34 A at the 600 V DC link for compatible downstream drive modules.
Specifications
| Manufacturer | Siemens |
|---|---|
| Order Number | 6SL3130-1TE22-0AA0 |
| Product Family | SINAMICS S120 |
| Module Type | Basic Line Module |
| Line Input | 3-phase 380–480 V AC |
| Input Frequency | 50/60 Hz |
| DC-Link Output | 600 V DC |
| Rated DC Output Current | 34 A |
| Rated Power | 20 kW |
| Construction | Booksize |
| Cooling Method | Internal air cooling |
| System Connection | DRIVE-CLiQ cable included |
| Product Lifecycle | PM300 Active Product |
Features
- Creates the common DC-link supply for a correctly engineered SINAMICS S120 drive group.
- Provides a 34 A DC output class suited to the documented 20 kW line-module rating.
- Fits the space-coordinated booksize mechanical system.
- Removes operating heat through its internal air-cooling path.
- Includes a DRIVE-CLiQ cable for system-topology connection.
Compatibility
- Use only within a compatible SINAMICS S120 booksize line-up.
- Confirm that the summed axis load, duty profile and energy flow are suitable for the 20 kW Basic Line Module.
- Coordinate line contactor, fusing, reactor or filter arrangements with the Siemens engineering documentation.
- Maintain cabinet inlet temperature, clearances and airflow needed by the internal cooling design.
- Do not select the 40 kW or 100 kW articles solely as mechanical replacements; ratings and installation requirements differ.
Replacement
- Retain the complete 6SL3130-1TE22-0AA0 order number in the spare-parts record.
- Capture the control-unit project, DC-link arrangement and connected Motor Module list before exchange.
- Compare line protection and cabinet cooling against the 20 kW, 34 A module data.
- Inspect power connectors and the common DC-link assembly for heat or mechanical damage.
- Following installation, confirm topology detection, DC-link stability and axis performance under controlled load.
FAQ
What differentiates 6SL3130-1TE22-0AA0 from 6SL3130-1TE24-0AA0?
The 1TE22 model is rated 20 kW and 34 A DC, while the 1TE24 model is rated 40 kW and 67 A DC.
What supply range is specified for this module?
The official product description gives a three-phase 380–480 V AC input at 50/60 Hz.
What DC-link output does the module provide?
Its rated output is 600 V DC at 34 A.
Does this exact model use external air cooling?
No. 6SL3130-1TE22-0AA0 is specified with internal air cooling.
Can it be selected only by matching kilowatts?
No. The complete order number, current class, line components, cooling and drive-system topology must all be checked.
What commissioning checks are appropriate after replacement?
Verify the DRIVE-CLiQ topology, line-side sequence, DC-link voltage, diagnostics and operation of every connected axis.
Recommended Models
| LP7-18-30A | 88974031 CB20 | L5508DSIP LE5508TSDSIP |
| 1399.19.0024 | GE IC660BBD025 | DT-2234B |
| WS-2 | 49Y7935 DAC 40GbE | AMX526 |
| ABB PSM0004 2RCA025059A0001N | E67I6DQ-O2 AS E67I6DC-O2 | VC7936ZZ11/U |
| Q61P | 1C31116G03 | S4-34415 |
| MC404A | J9734A | Allen Bradley 802T-DD |
| ABB G4001 2TME050080N0001 | RM-LP55 | T775B2040 |
| 03900 | LVCT01204S | ASI2314-B3 |
| 01151-0011-0032 | 15784 FIP CLIC 3V-2Z | MA1479A |
| 45123-3 | SP-RDM2 | ERP40 82125BK1000 |