Siemens 6SL3130-7TE21-6AA1 SINAMICS S120 Active Line Module
01Technical Summary
Siemens 6SL3130-7TE21-6AA1 is a 16 kW SINAMICS S120 Active Line Module in booksize construction. It converts a three-phase 380-480 V, 50/60 Hz line supply to a regulated 600 V DC link rated 27 A for a compatible S120 multi-axis drive system. The module uses internal air cooling and communicates through the engineered DRIVE-CLiQ topology.
02Specifications
| Manufacturer | Siemens |
|---|---|
| Article Number | 6SL3130-7TE21-6AA1 |
| Product Family | SINAMICS S120 |
| Module Type | Active Line Module |
| Construction | Booksize |
| Line Supply | Three-phase 380-480 V AC, 50/60 Hz |
| DC-Link Output | 600 V DC |
| Rated DC-Link Current | 27 A |
| Rated Power | 16 kW |
| Cooling | Internal air cooling |
| Communication | DRIVE-CLiQ |
| System Role | Regenerative infeed for a compatible S120 DC-link system |
03Features
Key Functions
- Creates the common DC-link supply for a compatible SINAMICS S120 multi-axis system.
- Active infeed technology supports controlled line-side operation and regenerative energy transfer in the approved configuration.
- The booksize format integrates with S120 line-side and motor-side modules.
- DRIVE-CLiQ provides communication and electronic identification within the engineered drive topology.
- Internal air cooling requires the specified cabinet airflow and installation clearances.
- The 16 kW and 27 A ratings must be checked against the complete load and regenerative duty.
Product Identity
- Manufacturer: Siemens
- Model: 6SL3130-7TE21-6AA1
- Product Type: SINAMICS S120 Active Line Module, Booksize
04Compatibility
- Use the module only with the approved Active Interface Module or other line-side components specified by Siemens.
- Confirm line voltage, short-circuit protection, grounding, EMC measures, 24 V electronics supply and DC-link busbar rating.
- Verify Control Unit, firmware, DRIVE-CLiQ topology, Motor Modules, motors, braking concept and commissioning software.
- Check cabinet dimensions, internal-air-cooling path, ambient conditions and derating.
- A newer Active Line Module revision must be evaluated using current Siemens compatibility documentation; matching power alone is not sufficient.
05Replacement & Lifecycle
- This AA1 article appears in Siemens S120 booksize service documentation for the 16 kW Active Line Module. Confirm current availability before procurement.
- The current 16 kW product record uses later hardware revisions; migration from AA1 requires a complete system review.
- Back up the drive project and record line-side components, Control Unit firmware, DRIVE-CLiQ topology, DC-link configuration and safety settings.
- Inspect and document busbars, connectors, 24 V supply, grounding and cabinet cooling before removal.
- After replacement, perform the Siemens commissioning procedure and verify line synchronization, DC-link voltage, regenerative operation, communications, alarms and all connected axes.
06Applications
Typical Uses
- Regenerative multi-axis SINAMICS S120 machine systems.
- Packaging, printing, converting, handling and production lines using a common DC link.
- Drive cabinets requiring a 16 kW booksize active infeed.
- Maintenance and engineered migration of an installed AA1 Active Line Module.
Selection Boundary
- Confirm the complete line-side configuration and 16 kW duty.
- Match the 600 V DC-link current, Control Unit, firmware and DRIVE-CLiQ topology.
- Review the current Siemens replacement documentation before selecting a later revision.
FAQFrequently Asked Questions
What is Siemens 6SL3130-7TE21-6AA1?
It is a 16 kW SINAMICS S120 booksize Active Line Module.
What line supply is specified?
The official S120 documentation identifies a three-phase 380-480 V, 50/60 Hz line supply for this module rating.
What DC-link rating does it provide?
The 16 kW module supplies a 600 V DC link rated 27 A in the approved system configuration.
Can it operate as a stand-alone drive?
No. It is a line-module component and requires the approved line-side equipment, Control Unit, DC-link system, Motor Modules and commissioned drive project.
Can a later hardware revision be installed directly?
Only after Siemens compatibility, line-side components, firmware, DRIVE-CLiQ, busbar and mechanical requirements have been checked.
What should be tested after installation?
Verify line synchronization, DC-link voltage, regenerative operation, DRIVE-CLiQ communication, alarms, thermal behavior and all connected axes.
+Recommended Models
| PAA2-4HVA-070 | ABB FCC/S 1.1.1.1 2CDG110210R0011 | LP7-18-30A |
| 330180-91-05 | 6ES7422-1HH00-0AA0 | ABB Q631 0072 R0111 |
| HSTN-RP01 L49029-003 | DXW-11-153-2 101655-01 | CPM500/2V |
| 3RP1540-1AJ30 | ZCK-1EG | C054045C001B |
| ABB 6126/01-83-500 | RK221825-AN | KX-HNC600 |
| LV434010 IFE-E3.16.36 | apbt320 | PCO3000AL0 |
| 108-309101-01、015-100123-04 | ABB 1SBP260181R1001 CP410M | 8DI ITEM3-2000U008000 |
| VS481B | QAM2112.200 | 6EV5000-1BC |
| BMXAMI0810 | IQE38-1201U50036 | SPI-10A |
| Opt8-m9+V1.1 | BIP-1300 | HE500TIU100C-212 |