Home>PLC>Siemens 6SL3210-1SE21-0AA0 SINAMICS S120 PM340 4 kW Filtered Power Module

Hot Categories

Siemens 6SL3210-1SE21-0AA0 SINAMICS S120 PM340 4 kW Filtered Power Module

Siemens 6SL3210-1SE21-0AA0 SINAMICS S120 PM340 4 kW Filtered Power Module

Item NO.: 3763391

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameSiemens 6SL3210-1SE21-0AA0 SINAMICS S120 PM340 4 kW Filtered Power Module
  • Item NO.3763391
  • Weight4.0000 kg = 8.8185 lb = 141.0958 oz
  • CategoryPLC
  • BrandSiemens
  • Creation Time2026-09-08
SINAMICS S120 | FSB filtered blocksize power module

Siemens 6SL3210-1SE21-0AA0 SINAMICS S120 PM340 4 kW Filtered Power Module

A 4 kW PM340 power stage for three-phase 380–480 V SINAMICS S120 systems, with integrated line filter and braking connection.

BrandSiemens
Model6SL3210-1SE21-0AA0
Product TypeSINAMICS S120 PM340 4 kW Filtered Power Module
01

Technical Summary

6SL3210-1SE21-0AA0 is a SINAMICS S120 PM340 blocksize Power Module with an integrated line filter. It is rated at 4 kW, uses frame size FSB and operates from a three-phase 380 to 480 V supply.

The module provides 10.2 A rated output current and 9.1 A high-overload base current. It is one part of a modular SINAMICS drive and requires a compatible Control Unit, line-side design and motor connection.

02

Specifications

Manufacturer Siemens
Article Number 6SL3210-1SE21-0AA0
Product Family SINAMICS S120 / PM340
Input Supply 3 AC 380–480 V, ±10%
Integrated Line Filter Yes; Category C2 installation with up to 25 m shielded motor cable
Rated Power 4 kW
High-overload Power 4 kW
Rated Output Current 10.2 A
High-overload Base Current 9.1 A
S6 Current, 40% Duty 10.8 A
Peak Current 20.4 A
Rated Pulse Frequency 4 kHz
Power Loss 0.18 kW
Cooling Air Requirement 0.009 m³/s
Sound Pressure at 1 m Below 50 dB
Rated Input Current 9.8 A with line reactor / 12.4 A without
UL Protection 15 A Class J, 65 kA SCCR
External Braking Resistor Greater than 160 Ω
Maximum Braking-resistor Cable 15 m
Protection / Frame IP20 or IPXXB; FSB
03

Features

  • Provides the blocksize AC power stage for a SINAMICS S120 drive axis.
  • Operates from a three-phase 380 to 480 V line supply under control of a compatible SINAMICS Control Unit.
  • Includes an integrated line filter in the AA0 configuration.
  • Supports a connected external braking resistor through the PM340 braking circuit.
  • Supplies 10.2 A rated output current with 20.4 A peak capability for the documented load cycle.
04

Compatibility

  • Use with a compatible SINAMICS S120 Control Unit and supported firmware for the installed machine.
  • The documented line-reactor selection for 6SL3210-1SE21-0AA0 is 6SL3203-0CD21-4AA0.
  • For the integrated-filter configuration, the Category C2 shielded motor-cable limit is 25 m.
  • The external braking resistor must be greater than 160 ω and its cable must not exceed 15 m.
  • Motor reactors, line protection and conductor sizes must be selected for the exact current and frame.
05

Replacement

  • Keep the complete 6SL3210-1SE21-0AA0 article number because the suffix identifies the filtered AA0 version.
  • Before replacement, record the Control Unit, firmware, motor data, parameter set and braking-resistor connection.
  • Match the FSB mechanical format, 4 kW rating and documented current profile.
  • Verify current product availability and any proposed migration against the installed SINAMICS architecture before ordering.
06

FAQ

What is the rated power of 6SL3210-1SE21-0AA0?

6SL3210-1SE21-0AA0 is rated at 4 kW; its high-overload type rating is 4 kW.

Which frame size is used by 6SL3210-1SE21-0AA0?

6SL3210-1SE21-0AA0 uses the FSB blocksize format.

Does 6SL3210-1SE21-0AA0 include a line filter?

Yes. The AA0 version includes an integrated line filter.

What output currents apply to 6SL3210-1SE21-0AA0?

The rated current is 10.2 A, the high-overload base current is 9.1 A, and peak current is 20.4 A.

Can 6SL3210-1SE21-0AA0 use an external braking resistor?

Yes. The resistance must be greater than 160 ω and the resistor cable is limited to 15 m.

What should be retained before replacing 6SL3210-1SE21-0AA0?

Back up the parameter set and record the Control Unit, firmware, motor, reactor, filter, braking and cabinet configuration.

You May Also Like