Siemens 6SL3351-6FE33-1AA1 MICROMASTER 430 Control Interface Board
A replacement control-interface board for the documented 3AC 380–480 V MICROMASTER 430 GX drive execution.
Overview
6SL3351-6FE33-1AA1 is a Siemens replacement Control Interface Board for MICROMASTER 430 drives. Siemens spare-parts documentation assigns it to frame size GX and the 3AC 380–480 V, 50/60 Hz, 310 A drive execution.
A Siemens maintenance instruction also lists 6SL3351-6FE33-1AA1 for the 160 kW MICROMASTER 430 GX drive MLFB 6SE6430-2UD41-6GA0. The host-drive label and project record remain mandatory because a control board is not selected by current class alone.
Specs
| Manufacturer | Siemens |
|---|---|
| Order Number | 6SL3351-6FE33-1AA1 |
| Product Type | Replacement Control Interface Board |
| Drive Family | MICROMASTER 430 |
| Frame Size | GX |
| Documented Supply Class | 3AC 380–480 V, 50/60 Hz |
| Documented Drive Current | 310 A |
| Maintenance-Instruction Context | 160.0 kW MICROMASTER 430 GX, MLFB 6SE6430-2UD41-6GA0 |
| Selection Evidence | Exact board code and complete host-drive MLFB |
| Configuration Evidence | Parameter backup, communication options and I/O assignment |
| Handling | Stored-energy isolation and ESD control |
| Acceptance | Drive diagnostics, I/O, communication, interlocks and controlled motor test |
Features
Restores the documented control-interface function in a MICROMASTER 430 GX drive.
Carries the exact FE33 family identity for the 310 A execution.
Supports service work when board and host-drive MLFB are controlled together.
Prevents confusion with GE-series MICROMASTER 440 boards that have similar Siemens numbering.
Applications
- Service replacement in the documented MICROMASTER 430 GX power range.
- Repair programs retaining the original drive, motor and cabinet engineering.
- Legacy-drive spares management requiring exact MLFB and parameter traceability.
Lifecycle
- Back up all parameters, I/O assignments, communication settings and fault history.
- Record the host MLFB, rating plate, board revision, connector positions and option modules.
- Investigate the power-stage or supply fault that may have damaged the original control-interface board.
- After installation, restore the approved dataset and test enable, direction, setpoint, I/O, communication and motor response.
FAQ
Why must the host MLFB accompany 6SL3351-6FE33-1AA1?
The official board record identifies a MICROMASTER 430 GX execution, while the complete drive MLFB confirms the installed rating and service context.
Can 6SL3351-6GE32-1AA1 replace 6SL3351-6FE33-1AA1?
No direct equivalence should be assumed: the FE33 board is documented for MICROMASTER 430 GX at 310 A, while the GE32 board is documented for MICROMASTER 440 FX at 210 A.
What backup is required before removing 6SL3351-6FE33-1AA1?
Save the full parameter set, digital and analog I/O map, communication configuration, motor data, option list and recent faults.
What upstream checks reduce repeat failure of 6SL3351-6FE33-1AA1?
Inspect control supplies, power-stage faults, grounding, cooling, contaminated connectors and any shorted external I/O circuit.
How should 6SL3351-6FE33-1AA1 be commissioned?
Use the approved parameter set, confirm diagnostics and interlocks, then perform a controlled unloaded and loaded motor test.
Recommended Models
| Siemens 1PH7133-2HF02-0BB3 | DDS02.2-W100-B 263406 DSM02.3-FW 265398 | Siemens 6SL3000-0DE28-0AA0 |
| AKEC-212R | LA6-3DTNUN-YBG-002654-01 | 67CFR 250PSI/0-125PSI |
| EL4014 | LS406C26604520 | Expi-4 AudiaEXPI-4 |
| 80B7 6400 CEPL130201-02 | 6AV3515-1MA20-1AA0 | S903 |
| 8BOC0160HW00.001-1 | FTL51-AGR2BB4Y9A | C7676 A5E00726988 |
| Siemens 3RW4447-6BC44 | ZTR 2.5 1831280000 | MCS 12D41-RV0B0-Z0E0-KK6S00N-R0SU |
| ABB 3BSE008510R1 | ABB DI810 3BSE008508R1 | TA25DU25 1SAZ211201R1051 |
| X20DO9322 | AES75-12 | 140S-MC1-3-1K1-2K |
| RS3251 | BZME1-A32-BT | CEM-M2-C60-PZ-SE-161320 |
| OAW-AP1201H | Siemens 1PC30111CA002AB2 | 30/381.001.0 7062027 |