Home>DCS>Triconex 3721 Tricon 32-Channel Differential TMR Analog Input Module

Hot Categories

Triconex 3721 Tricon 32-Channel Differential TMR Analog Input Module

Triconex 3721 Tricon 32-Channel Differential TMR Analog Input Module

Item NO.: 3721

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameTriconex 3721 Tricon 32-Channel Differential TMR Analog Input Module
  • Item NO.3721
  • Weight2.0200 kg = 4.4533 lb = 71.2534 oz
  • CategoryDCS
  • BrandTriconex
  • Creation Time2025-09-23
Triconex 3721 Tricon 32-Channel Differential TMR Analog Input Module
Tricon v10.2 and LaterENGINEERING RECORD

32 DIFFERENTIAL INPUTS · 0–5 V OR ±5 V · 10 MS UPDATE

Triconex 3721 Tricon 32-Channel Differential TMR Analog Input Module

A thirty-two-channel DC-coupled differential analog input module for supported Tricon v10.2-and-later systems.

Input points32 differential
Voltage ranges0–5 V / −5 to +5 V
Update rate10 ms
01
EXACT EXECUTION

Product Identification

3721 is a TMR analog input module with thirty-two differential, DC-coupled channels. Its selectable voltage ranges are 0 to 5 VDC and −5 to +5 VDC, with 12-bit or 14-bit programmable resolution.

Tricon documentation limits installation to version 10.2 and later systems. A 0–20 mA field signal can be measured when the documented 250 Ω shunt arrangement is used.

02
VERIFIED ATTRIBUTES

Engineering Data

Manufacturer
Schneider Electric / Triconex
Exact model
3721
Architecture
TMR analog input
Input signals
32 differential, DC-coupled
Voltage ranges
0–5 VDC or −5 to +5 VDC
Current measurement
0–20 mA with 250 Ω shunt resistor
Input update rate
10 ms
Resolution
12 or 14 bit, programmable
Accuracy
Less than 0.15% of full scale, 0 to 60 °C
Input resistance
10 MΩ minimum, powered
Common-mode range
−12 to +12 V peak
Field-to-system isolation
800 VDC minimum
Module indicators
Pass, Fault, Active and Field
System compatibility
Tricon v10.2 and later
03
SYSTEM ROLE

Functions

A

Differential measurement

Thirty-two DC-coupled channels measure signals independently of a shared signal return.

B

Programmable resolution

The project selects 12-bit or 14-bit conversion according to the approved configuration.

C

Voltage or shunt-current use

Native voltage ranges also support a documented 0–20 mA loop through a 250 Ω shunt.

D

Fast station update

The published input update rate is 10 ms.

IndustryParts industrial automation support
INDUSTRIAL PARTS SUPPORT

About IndustryParts

https://www.industryparts.com/

Exact identity before quotation

IndustryParts prepares 3721 enquiries around the complete manufacturer label, requested quantity and destination. For controlled replacements, include the host-system record, field photographs and configuration evidence that apply to this exact execution.

Complete labelRevision retainedApplication evidence
04
APPLICATION FIT

Applications

Differential transmitter inputs

Acquiring supported voltage signals where common-mode performance is important.

Current-loop conversion

Measuring documented 0–20 mA loops through the approved 250 Ω termination.

Tricon v10.2 modernization

Adding or replacing the module only after chassis, software and termination compatibility are confirmed.

05
MAINTENANCE RECORD

Lifecycle

01

Document

Capture range, resolution, shunt values, channel scaling, alarms and system release.

02

Wire

Verify polarity, common-mode conditions, termination and point-to-point loop evidence.

03

Calibrate

Apply known values across each active range and record accuracy, diagnostics and safety response.

06
PRACTICAL REVIEW

FAQ

Q01

Which Tricon release supports 3721?

The reviewed Tricon documentation specifies installation in version 10.2 and later systems.

Q02

Can 3721 read 0–20 mA directly?

The documented method uses a 250 Ω shunt resistor to convert the current signal for the voltage input.

Q03

What should accompany a 3721 enquiry?

Provide the full label, system release, slot, field termination, selected range, resolution, shunt values and channel map.

Q04

Why is common-mode voltage important for 3721?

The published input common-mode range is −12 to +12 V peak; exceeding it can compromise proper module operation.

Q05

How should 3721 be accepted after replacement?

Inject controlled values on all active channels and verify scaling, diagnostics, alarm thresholds and every affected safety action.

ENQUIRY INFORMATION

Send the complete 3721 label, requested quantity and destination.

You May Also Like