Home>DCS>Triconex 3809AX Tricon CX 16-Channel HART Analog Output Module

Hot Categories

Triconex 3809AX Tricon CX 16-Channel HART Analog Output Module

Triconex 3809AX Tricon CX 16-Channel HART Analog Output Module

Item NO.: 3810619

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameTriconex 3809AX Tricon CX 16-Channel HART Analog Output Module
  • Item NO.3810619
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandTriconex
  • Creation Time2026-10-27
Triconex 3809AX Tricon CX 16-Channel HART Analog Output Module
Tricon CX Safety SystemPRODUCT RECORD

16 ANALOG OUTPUTS · 4–20 MA · HART · TMR

Triconex 3809AX Tricon CX 16-Channel HART Analog Output Module

A sixteen-point Tricon CX analog output module for controlled 4–20 mA field loops with HART communication.

Output points16
Signal range4–20 mA
ArchitectureTMR with HART
01
PRODUCT CONTEXT

Overview

3809AX is the 16-point analog output assembly in the Tricon CX I/O family. Schneider documentation identifies the 3809X/3809AX family for 4–20 mA output service with HART and Triple Modular Redundant architecture.

Field termination is part of the module boundary. The published Tricon CX arrangement pairs this family with the 9890X-610 termination panel, so the module, termination, cable, loop power and HART asset record should be reviewed together.

02
CONTROLLED DATA

Specifications

Manufacturer
Schneider Electric / Triconex
Exact model
3809AX
System family
Tricon CX
Module type
TMR analog output with HART
Output channels
16
Published output service
4–20 mA
Catalog operating span
0–23 mA
HART support
Yes
Compatible termination panel
9890X-610
Field terminals
One positive and one negative connection per point
Unused point treatment
No shorting requirement stated for unused points
03
FUNCTIONAL PROFILE

Features

A

Triplicated output processing

TMR architecture supports the fault-tolerant Tricon CX output path.

B

HART maintenance path

HART communication allows supported field-device information to share the analog loop.

C

Sixteen-point density

One module presents sixteen controlled current-output channels.

D

Defined termination route

The 9890X-610 field panel keeps loop landing and module identity tied to one documented interface.

IndustryParts industrial automation support
INDUSTRIAL PARTS SUPPORT

About IndustryParts

https://www.industryparts.com/

Exact identity before quotation

IndustryParts prepares 3809AX enquiries around the complete manufacturer label, requested quantity and destination. For controlled replacements, include the host-system record, field photographs and configuration evidence that apply to this exact execution.

Complete labelRevision retainedApplication evidence
04
FIELD USE

Applications

Safety-system final elements

Driving documented 4–20 mA final-control loops in a Tricon CX project.

HART-enabled actuator loops

Maintaining current command and supported HART access through the approved termination route.

Exact-module service

Restoring a 3809AX position while retaining termination, cable and project evidence.

05
SERVICE DISCIPLINE

Lifecycle

01

Capture

Archive the project, output scaling, safe state, HART assignments and loop-power arrangement.

02

Isolate

Place affected final elements in the approved safe or manual condition before field work.

03

Validate

Stroke every returned loop, compare command with measured current and close all diagnostics.

06
CUSTOMER QUESTIONS

FAQ

Q01

What should be supplied with a 3809AX quotation request?

Include the complete AX label, chassis position, TriStation project revision, 9890X-610 termination details, cable identity and loop schedule.

Q02

Is a 3809X automatically interchangeable with 3809AX?

No. The common family description does not replace an execution and compatibility review for the installed Tricon CX release.

Q03

How should HART data be handled during a 3809AX replacement?

Preserve device tags, polling assignments and asset records, then verify supported HART communication after the current loop is proven.

Q04

What prevents a live-loop error on 3809AX?

Use the approved isolation plan, identify each positive and negative terminal, and keep every final element in its defined safe condition.

Q05

What evidence closes a 3809AX replacement?

Record commanded and measured current at controlled points, final-element travel, HART communication, channel diagnostics and safety-function testing.

ENQUIRY INFORMATION

Send the complete 3809AX label, requested quantity and destination.