Home>DCS>Woodward 9907-151 ProTech 203 220 V AC De-energize-to-Trip Overspeed Protection System

Hot Categories

Woodward 9907-151 ProTech 203 220 V AC De-energize-to-Trip Overspeed Protection System

Woodward 9907-151 ProTech 203 220 V AC De-energize-to-Trip Overspeed Protection System

Item NO.: 3821611

Warranty: 1 year 


Condition : brand new in factory sealed box


Email: sales@mvme.cn


Chat online: +86 18030175807

Detail

  • Product NameWoodward 9907-151 ProTech 203 220 V AC De-energize-to-Trip Overspeed Protection System
  • Item NO.3821611
  • Weight1.0000 kg = 2.2046 lb = 35.2740 oz
  • CategoryDCS
  • BrandWoodward
  • Creation Time2026-11-05
PROTECH 203 OVERSPEED PROTECTION SYSTEM · EXACT ARTICLE CONTROL · INDUSTRIAL AUTOMATION

Woodward 9907-151 ProTech 203 220 V AC De-energize-to-Trip Overspeed Protection System

A three-unit ProTech 203 execution with 220 V AC input on units A, B and C and de-energize-to-trip relay logic.

01
PRODUCT CONTEXT

Product Overview

9907-151 is the 220 V AC, de-energize-to-trip ProTech 203 system part number. All three independent speed-sensing units use the same 220 V AC supply class.

The permitted supply range for each unit is 180 to 264 V AC with a listed consumption of 16.4 VA. Each unit receives a magnetic-pickup signal and contributes to the hardware two-out-of-three trip vote.

The exact part number controls both supply and relay philosophy. A different 9907-series ProTech 203 number must not be selected only because the enclosure or front panel appears similar.

02
PERFORMANCE RECORD

Performance

OPERATING ROLE 01

Sense three independent speeds

Units A, B and C each calculate speed from their own magnetic-pickup signal.

OPERATING ROLE 02

De-energize on the trip decision

The 9907-151 execution uses de-energize-to-trip logic for the documented relay arrangement.

OPERATING ROLE 03

Vote two out of three

Hardware voting requires two trip paths to produce the system trip output.

03
CONTROLLED DATA

Technical Details

Manufacturer Woodward Exact model 9907-151
Product family ProTech 203 Trip execution De-energize to trip
Unit A supply 220 V AC Unit B supply 220 V AC
Unit C supply 220 V AC Permitted input range 180 to 264 V AC per unit
Power requirement 16.4 VA per unit Speed inputs Three magnetic pickups
Trip vote Two out of three

About IndustryParts

https://www.industryparts.com/

Supply and relay philosophy are verified together

IndustryParts keeps the 9907-151 identity, three-unit power record and protection evidence together before preparing a quotation.

  • •Exact submitted model retained
  • •Installed-system evidence reviewed
  • •Requested quantity linked to the enquiry
IndustryParts industrial automation support
04
SYSTEM PATH

System Integration

STEP 01

Verify all three supplies

Record isolation, branch protection, grounding and the independent supply wiring for units A, B and C.

STEP 02

Archive trip interfaces

Capture the overspeed settings, relay terminal schedule and turbine shutdown logic.

STEP 03

Retain sensor evidence

Document each MPU, cable, tooth count, normal speed and overspeed test method.

STEP 04

Complete the protection test

Verify all speed channels, de-energize relay action, voting and final trip-system response.

05
APPLICATION FIT

Applications

Turbine overspeed protection

Providing three independent magnetic-pickup channels and a voted shutdown decision.

220 V AC installations

Maintaining the exact three-unit power execution documented by the 9907-151 part number.

Legacy protection-system service

Replacing controlled components while retaining settings, relay philosophy and final trip evidence.

06
CUSTOMER QUESTIONS

FAQ

Q01

Can a 9907-150 replace 9907-151?

No automatic substitution should be made: 9907-150 is an energize-to-trip execution, while 9907-151 is the de-energize-to-trip 220 V AC system.

Q02

What power evidence should accompany 9907-151?

Provide the supply voltage, branch protection and terminal records for units A, B and C, not only the enclosure nameplate.

Q03

Why must all three MPU records be retained for 9907-151?

Each unit calculates speed independently, so sensor type, tooth count, gap and cable evidence are needed for every channel.

Q04

How should the voting path be checked after 9907-151 service?

Prove each channel and then verify the documented two-out-of-three relay action through the turbine shutdown interface.

Q05

What closes a 9907-151 replacement record?

Matched part number, correct de-energize behavior, stable speed indication, verified voting and a completed trip-system test provide acceptance evidence.

ENQUIRY INFORMATION

Request a model-specific quotation

Send the complete 9907-151 label, requested quantity, delivery destination and installed-system context.

You May Also Like