Sixteen current inputs
Concentrates sixteen documented 4–20 mA field loops in one FIO module.
Warranty: 1 year
Condition : brand new in factory sealed box
Email: sales@mvme.cn
Chat online: +86 18030175807
A 16-channel 4–20 mA input module with HART communication and the ATK4A-00 KS cable interface adapter.
AAI143-H50/K4A00 provides sixteen isolated 4–20 mA inputs and supports HART digital communication. Yokogawa decodes H as the HART execution, 5 as no explosion protection, 0 as the basic type and /K4A00 as the supplied ATK4A-00 KS cable interface adapter for an AEA4D terminal board.
The module updates data every 10 ms and permits 2-wire or 4-wire transmitter selection by channel. The complete suffix and option code must remain with the field-termination record.
Yokogawa
AAI143-H50/K4A00
16
4–20 mA
HART protocol
No explosion protection
Basic type
ATK4A-00 KS cable interface adapter for AEA4D
24 mA
±16 µA
10 ms
270 Ω at 20 mA to 350 Ω at 4 mA
2-wire or 4-wire by channel setting pin
Concentrates sixteen documented 4–20 mA field loops in one FIO module.
Provides digital communication on the supported field loops while retaining the analog process signal.
Allows the 2-wire or 4-wire transmitter mode to be set for each channel.
Uses the /K4A00 adapter to route the module to the documented AEA4D termination.
Confirm the AEA4D terminal board, KS cable and channel-by-channel transmitter selection for AAI143-H50/K4A00.
Retain the installed host, project and connection evidence that defines the approved use of this execution.
Complete the model-specific checks described in the service sequence before return to operation.
Reading analog process values and supported HART information from field devices.
Maintaining a documented KS-cable path through the supplied interface adapter.
Restoring the same channel modes, ranges and termination without cross-wiring.
It identifies HART communication, no explosion protection, the basic execution and the ATK4A-00 KS cable adapter.
Not when the application requires the documented HART communication and /K4A00 termination path.
Provide the full H50/K4A00 label, AEA4D and KS cable records, channel list, transmitter modes and quantity.
Yokogawa states that a Zener barrier is not allowed; use an isolation barrier for intrinsically safe applications.
Correct channel values, documented 2-wire or 4-wire modes, HART access and clean diagnostics close the test.
IndustryParts prepares AAI143-H50/K4A00 enquiries around the complete manufacturer label, requested quantity and installed-system evidence. Share the application record that distinguishes this execution before a supply proposal is prepared.
Send the complete AAI143-H50/K4A00 label, requested quantity and delivery destination.