Extends CENTUM VP field I/O through a dual-redundant ESB Bus node architecture.
Product Identification
ANB10D-427/CU2T/NDEL is a Yokogawa CENTUM VP node unit for dual-redundant ESB Bus architecture. Every suffix segment defines part of the supplied execution.
Yokogawa coding identifies -4 as dual-redundant power supply, 2 as 220–240 VAC and 7 as the ISA Standard G3 option without explosion protection.
/CU2T supplies two connector units with terminators, while /NDEL is the Node Expansion software license required for the specified expanded node connection.
Engineering Data
Functions
Provides the exact dual-power and 220–240 VAC execution encoded by -427.
Includes two terminated connector units under the /CU2T option.
Carries the /NDEL node-expansion license required for the documented connection.
Applications
- CENTUM VP field I/O node expansion in supported FCS architectures.
- Dual-redundant ESB Bus installations using the stated 220–240 VAC supply class.
- ISA G3 environmental installations without explosion-protection certification.
- Licensed node expansion that requires the /NDEL option.
Lifecycle
- Record the complete node, FCS, power, ESB Bus, connector-unit and license identities.
- Back up engineering data and document both redundant bus paths before service.
- Verify the installed environment, grounding, terminations and power feeds against the exact -427 execution.
- After installation, confirm node recognition, both power feeds, both bus paths, I/O communications and license state.
FAQ
Q01What should accompany an ANB10D-427/CU2T/NDEL enquiry?
Send the full node label, FCS model, engineering release, bus topology, power feeds, connector-unit labels, license record, quantity and destination.
Q02Can ANB10D-427/CU2T/NDEL be shortened to ANB10D when ordering?
No. The -427, /CU2T and /NDEL segments define power, voltage, environmental, connector and license content.
Q03What must be preserved before replacing ANB10D-427/CU2T/NDEL?
Preserve the project, node address, I/O allocation, redundant bus paths, terminator locations and the node-expansion license record.
Q04What redundancy test is appropriate after service?
Verify each power feed and ESB Bus path independently under the approved CENTUM VP procedure while confirming stable node communications.
Q05What proves ANB10D-427/CU2T/NDEL is ready?
Confirm the exact execution, both connector units and terminators, active license, clean diagnostics and tested redundant paths.
About IndustryParts
https://www.industryparts.com/Every option code remains visible in the node record
IndustryParts keeps ANB10D-427/CU2T/NDEL tied to its FCS, redundant bus topology, connector units and license evidence.
- All suffix codes retained